Suppr超能文献

[使用扫描激光检眼镜对视网膜神经纤维层进行成像的可能性]

[Possibilities for imaging the retinal nerve fiber layer with the scanning laser ophthalmoscope].

作者信息

Rohrschneider K, Kruse F E, Burk R O, Völcker H E

机构信息

Universitäts-Augenklinik Heidelberg.

出版信息

Ophthalmologe. 1995 Aug;92(4):515-20.

PMID:7549339
Abstract

BACKGROUND

Documentation of the retinal nerve fiber layer using red free light is not established as a routine method. The reasons for this are the difficulties involved in taking the pictures and developing them, especially in glaucoma patients, and the need for maximum pupil dilation. The scanning laser ophthalmoscope (SLO) allows fast and easy documentation of the fundus with the possibility of simultaneous image control during the examination.

PATIENTS AND METHODS

Nerve fiber layer images of 48 eyes of 25 patients taken with the argon blue light of the SLO were compared to conventional photographs of the nerve fiber layer with red-free light. In addition, we compared documentation of the nerve fiber layer using argon-blue or argon-green light in the SLO.

RESULTS

The nerve fiber layer images obtained with the SLO were of good quality for all 48 eyes included in the study, whereas with conventional photography we could not obtain images in 9 eyes. There was a high correlation between the two methods in the detection of localized damage or zones with diffuse nerve fiber atrophy for the 39 eyes documented with both methods, and there was better image quality in some using the SLO. The use of blue light permits the nerve fiber layer to be seen more easily than with green light.

CONCLUSIONS

The SLO allows nerve fiber bundle defects or diffuse atrophy to be detected similar to conventional fundus photographs using red free light sources. There is no further need to dilate the pupil maximally due to the confocal principle and the scanning technique. The smaller angle of view of the SLO requires fixation movements of the patient being examined for the detection of beginning peripheral nerve fiber bundle defects.

摘要

背景

使用无赤光记录视网膜神经纤维层尚未成为一种常规方法。原因在于拍照和冲洗照片存在困难,尤其是在青光眼患者中,并且需要最大程度地散瞳。扫描激光检眼镜(SLO)能够快速、轻松地记录眼底,并且在检查过程中可以同时进行图像控制。

患者与方法

将25例患者48只眼用SLO的氩蓝光照相获得的神经纤维层图像与用无赤光拍摄的神经纤维层传统照片进行比较。此外,我们还比较了在SLO中使用氩蓝光或氩绿光记录神经纤维层的情况。

结果

在纳入研究的所有48只眼中,用SLO获得的神经纤维层图像质量良好,而用传统摄影方法时,有9只眼无法获得图像。对于两种方法都记录的39只眼,在检测局部损伤或弥漫性神经纤维萎缩区域方面,两种方法之间存在高度相关性,并且在一些情况下使用SLO图像质量更好。使用蓝光比使用绿光更容易看到神经纤维层。

结论

SLO能够检测到神经纤维束缺陷或弥漫性萎缩,类似于使用无赤光源的传统眼底照片。由于共焦原理和扫描技术,无需再最大程度地散瞳。SLO较小的视角要求被检查患者进行注视运动,以便检测早期周边神经纤维束缺陷。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验