• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Using simulation data to predict lung geometry for inhomogeneity corrections in breast cancer treatments.

作者信息

Chen W, Chu J C, Griem K, Hartsell W F, Saxena V S

机构信息

Department of Medical Physics, Rush-Presbyterian-St. Luke's Medical Center, Chicago, IL 60612, USA.

出版信息

Int J Radiat Oncol Biol Phys. 1995 Oct 15;33(3):683-8. doi: 10.1016/0360-3016(95)00171-T.

DOI:10.1016/0360-3016(95)00171-T
PMID:7558959
Abstract

PURPOSE

To develop a statistical model based only on simulation measurement data, to predict the lung geometry in the central slice of the tangential radiation treatment fields for breast cancer.

METHODS AND MATERIALS

A linear regression analysis was performed on 22 patients to determine the shape of lung in the central axis plane of the tangential radiation fields. Data collected include the greatest perpendicular distance (GPD) measured from the chest wall to the field border on computed tomography (CT) images, the central lung distance (CLD) measured from the posterior field border to the chest wall on the simulation portal images, and the lung contours digitized at 1 cm intervals. The lung contours of these patients were fitted to a parabolic curve through a polynomial regression model. A lung template based on the regression model is used to construct a "generic lung" contour on patients' external body contours for treatment planning. The accuracy of this technique was tested on another group of 15 patients for its ability to predict the shape of lung on the central axis plane and the accuracy of dose to the prescription point.

RESULTS

The polynomial regression indicates that all the patients' lung contours in the tangential fields follow a parabolic curve: Y = -0.0808 X2 + 0.0096 X + 0.0326. The maximum lung involvement (GPD) can be determined from the value of CLD measured on the simulation film by the linear regression model with a determination coefficient of 0.712. The 15-patient test results indicate that our model predicts the lung separation on the central axis with an average deviation of 1.35 cm, and the average absolute dose deviation to the dose prescription point is 1.46%.

CONCLUSION

The model presented in this article provides an efficient method to estimate the lung geometry for breast cancer treatment planning without the requirement of CT data. The lung contour predicted by our model is useful for calculating dose distributions with inhomogeneity correction and may potentially benefit patients at higher risk of pulmonary toxicity.

摘要

相似文献

1
Using simulation data to predict lung geometry for inhomogeneity corrections in breast cancer treatments.
Int J Radiat Oncol Biol Phys. 1995 Oct 15;33(3):683-8. doi: 10.1016/0360-3016(95)00171-T.
2
Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer?模拟测量能否用于预测乳腺癌患者切线野照射的肺体积?
Int J Radiat Oncol Biol Phys. 1990 Jan;18(1):181-7. doi: 10.1016/0360-3016(90)90282-o.
3
Dosimetric analysis of intact breast irradiation in off-axis planes.
Int J Radiat Oncol Biol Phys. 1997 Aug 1;39(1):261-7. doi: 10.1016/s0360-3016(97)00292-7.
4
Lung and heart dose volume analyses with CT simulator in radiation treatment of breast cancer.乳腺癌放射治疗中使用CT模拟机进行肺和心脏剂量体积分析。
Int J Radiat Oncol Biol Phys. 1998 Aug 1;42(1):11-9. doi: 10.1016/s0360-3016(98)00200-4.
5
Comparison of a lung fitting algorithm with CT data for tangential fields in radiotherapy of the breast.用于乳腺癌放疗中切线野的肺部拟合算法与CT数据的比较。
Br J Radiol. 2004 May;77(917):414-9. doi: 10.1259/bjr/51786246.
6
Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device.
Int J Radiat Oncol Biol Phys. 1995 Jan 15;31(2):411-7. doi: 10.1016/0360-3016(94)00280-X.
7
Patterns of dose variability in radiation prescription of breast cancer.乳腺癌放射治疗处方中的剂量变异性模式。
Radiother Oncol. 1997 Jul;44(1):83-9. doi: 10.1016/s0167-8140(97)00054-6.
8
Computerized treatment planning in radiation therapy of intact breast: influence of number of CT-cuts.
J Egypt Natl Canc Inst. 2005 Jun;17(2):76-84.
9
Estimating the volume of lung irradiated during tangential breast irradiation using the central lung distance.
Br J Radiol. 1995 Sep;68(813):1004-8. doi: 10.1259/0007-1285-68-813-1004.
10
[Dosimetric assessment of external treatment plans for breast cancer: the significance of dose prescription selection].
Magy Onkol. 2005;49(3):235-7, 240-3. Epub 2005 Oct 25.

引用本文的文献

1
Predictive parameters for selection of electronic tissue compensation radiotherapy in early-stage breast cancer patients after breast-conserving surgery.保乳手术后早期乳腺癌患者电子组织补偿放疗选择的预测参数
Oncotarget. 2016 May 31;7(22):32835-45. doi: 10.18632/oncotarget.9054.