Suppr超能文献

1992年美国血液及血液成分的采集与输血情况

Collection and transfusion of blood and blood components in the United States, 1992.

作者信息

Wallace E L, Churchill W H, Surgenor D M, An J, Cho G, McGurk S, Murphy L

机构信息

Center for Management Systems, Snowmass Village, Colorado, USA.

出版信息

Transfusion. 1995 Oct;35(10):802-12. doi: 10.1046/j.1537-2995.1995.351096026360.x.

Abstract

BACKGROUND

Studies were conducted to measure the state of the United States' national blood resource in 1992 and changes therein from 1989.

STUDY DESIGN AND METHODS

With data supplied by the American Red Cross and the American Association of Blood Banks, as well as data from a stratified random-sample survey of 3350 non-American Association of Blood Banks hospitals, statistical methods were applied to estimate national blood activities in 1992.

RESULTS

The total US blood supply in 1992 was 13,794,000 units, a decrease of 3.1 percent from 1989. Some 11,307,000 red cell units were transfused to 3,772,000 patients, an average of 3.0 units per transfused patient. Preoperative autologous blood deposits totaled 1,117,000 units, a 70-percent increase over 1989. Of this number, 566,000 units (50.7%) were transfused, 5,000 (4.4%) transferred to the allogeneic supply, and 546,000 (48.9%) discarded. Of 436,000 directed-donation units, 136,000 (31.2%) were transfused, 57,000 (13.1%) transferred to allogeneic supply, and 243,000 (55.7%) discarded. The total allogeneic blood supply, including imports, decreased by 7.4 percent from 1989, and allogeneic blood transfusions, including those to children, decreased by 8.6 percent. Over 8,300,000 platelet units were transfused; of these, some 3,600,000 were apheresis platelets. In addition, 2,255,000 units of plasma and 939,000 units of cryoprecipitate were transfused.

CONCLUSION

While the US blood supply was adequate for transfusion needs in 1992, blood collections and red cell transfusions had decreased substantially since 1989.

摘要

背景

开展了多项研究以评估1992年美国国家血液资源状况及其自1989年以来的变化。

研究设计与方法

利用美国红十字会和美国血库协会提供的数据,以及对3350家非美国血库协会医院进行分层随机抽样调查的数据,运用统计方法估算1992年的全国血液活动情况。

结果

1992年美国血液供应总量为1379.4万单位,较1989年减少了3.1%。约1130.7万单位红细胞被输注给377.2万名患者,每位接受输血的患者平均输注3.0单位。术前自体血储存总量为111.7万单位,比1989年增加了70%。其中,56.6万单位(50.7%)被输注,5000单位(4.4%)转入异体血供应,54.6万单位(48.9%)被废弃。在43.6万单位定向捐赠血液中,13.6万单位(31.2%)被输注,5.7万单位(13.1%)转入异体血供应,24.3万单位(55.7%)被废弃。包括进口血液在内的异体血供应总量较1989年减少了7.4%,包括儿童输血在内的异体血输注量减少了8.6%。超过830万单位血小板被输注;其中约360万单位是单采血小板。此外,还输注了225.5万单位血浆和93.9万单位冷沉淀。

结论

尽管1992年美国的血液供应足以满足输血需求,但自1989年以来采血和红细胞输注量大幅下降。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验