The influence of splinting procedures on the periodontal and peri-implant tissue damping characteristics. A longitudinal study with the Periotest device.

作者信息

Naert I E, Rosenberg D, van Steenberghe D, Tricio J A, Nys M

机构信息

Department of Prosthetic Dentistry, Faculty of Medicine, Catholic University of Leuven, Belgium.

出版信息

J Clin Periodontol. 1995 Sep;22(9):703-8. doi: 10.1111/j.1600-051x.1995.tb00830.x.

Abstract

The aim of the present study was to evaluate the capability of the Periotest device in detecting and monitoring functional changes in the periodontal as well as in the pari-implant damping characteristics. In the first part of this study, 107 teeth were splinted by means of 40 full acrylic fixed prostheses (AFP) and another 37 teeth were splinted by means of 14 ceramometallic fixed prostheses (C-MFP). The Periotest measurements of individual teeth were done the day the fixed prostheses were cemented temporary (PTV 1), and again after a mean observation period of 27.4 days (PTV 2). In the 2nd part, 78 osseointegrated two-stage implants were splinted by means of 23 full acrylic fixed prosthesis (AFP) and other 18 implants were left without it. Using the same abutment length, Periotest measurements were performed, at abutment connections and before installation of the final prosthesis. In a 3rd part, using both implants and teeth as abutments, 29 osseointegrated implants were connected with 25 abutment teeth by means of 7 AFP. The measurements were performed at the beginning of the prosthetic treatment and 2, 4 and 6 weeks later. After splinting teeth by means of AFP for the observation period, no statistically significant reduction in PTVs was found. When on the other hand, a C-MFP was used, PTV 2 showed a significant reduction. The PTVs at abutment connection went down after a period of time, during which some implants were interconnected by means of an AFP and others were not.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究的目的是评估Periotest设备检测和监测牙周以及种植体周围阻尼特性功能变化的能力。在本研究的第一部分,107颗牙齿通过40个全丙烯酸固定义齿(AFP)进行夹板固定,另外37颗牙齿通过14个烤瓷金属固定义齿(C-MFP)进行夹板固定。在固定义齿临时粘固当天(PTV 1)对各颗牙齿进行Periotest测量,并在平均观察期27.4天后再次测量(PTV 2)。在第二部分,78颗骨结合式两段式种植体通过23个全丙烯酸固定义齿(AFP)进行夹板固定,另外18颗种植体未进行夹板固定。在相同基台长度下,在基台连接处和安装最终义齿之前进行Periotest测量。在第三部分,使用种植体和牙齿作为基台,29颗骨结合式种植体通过7个AFP与25颗基牙相连。在修复治疗开始时以及2、4和6周后进行测量。在通过AFP对牙齿进行夹板固定的观察期后,未发现PTV有统计学意义的降低。另一方面,当使用C-MFP时,PTV 2显示出显著降低。经过一段时间后,基台连接处的PTV下降,在此期间,一些种植体通过AFP相互连接,而另一些则没有。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验