Björklund L J, Malmgren N, Lindroth M
Department of Pediatrics, University Hospital, Lund, Sweden.
Pediatr Radiol. 1995;25(2):149-52. doi: 10.1007/BF02010332.
Umbilical venous catheters that are pushed in too far will usually cross the atrial septum and may dislodge in a pulmonary vein. The authors report eight neonates with radiographic documentation of this catheter malposition together with either a localized pulmonary opacification or an autopsy report of a pulmonary hemorrhage or infarction corresponding to the catheter position. The lung injury ranged from a transient edema to hemorrhagic pulmonary infarction and hydrothorax. In two cases autopsy demonstrated localized infarction without previous radiographic signs of catheter-related injury.
脐静脉导管插入过深通常会穿过房间隔,可能会移位至肺静脉。作者报告了8例新生儿,其导管位置异常有影像学记录,同时伴有局部肺实变,或有与导管位置相应的肺出血或梗死的尸检报告。肺损伤范围从短暂性水肿到出血性肺梗死和胸腔积液。在两例尸检中,发现有局部梗死,而之前并无导管相关损伤的影像学征象。