Suga K, Nishigauchi K, Matsumoto T, Kume N, Uchisako H, Matsunaga N
Department of Radiology, Yamaguchi University, School of Medicine.
Nihon Igaku Hoshasen Gakkai Zasshi. 1994 Dec 25;54(14):1424-6.
We investigated preliminary the clinical utility of dynamic SPECT in studying pulmonary Xenon-133 gas washout, using the continuous repetitive rotating acquisition method with a triple-headed SPECT system. The subjects included one healthy volunteer and 16 various lung diseases. After obtaining the equilibrium images, the sequential washout images were acquired every 60 sec for 6 min. As the ventilation index, the real half-time of regional activity was evaluated. With or without abnormalities on chest CT, these images allowed us to show effectively the three-dimensional distribution of ventilation abnormalities, such as peripheral or segmental air trapping.