Comparative analysis of saphenous vein bypass vs. native coronary artery balloon angioplasty: technical differences and angiographic response.

作者信息

Kimball B P, Bui S

机构信息

Department of Medicine, Toronto Hospital (General Division), Ontario, Canada.

出版信息

Cathet Cardiovasc Diagn. 1995 Apr;34(4):293-9; discussion 300. doi: 10.1002/ccd.1810340204.

DOI:10.1002/ccd.1810340204
PMID:7621538
Abstract

To evaluate technical differences and angiographic response of saphenous vein bypass graft angioplasty in comparison to native coronary arteries, we retrospectively analyzed 54 patients undergoing this procedure at The Toronto Hospital between February 1988 and May 1993. These subjects were temporally matched to a cohort of successful native coronary angioplasties, with comparison of technical parameters, pre-existing qualitative/quantitative (Cardiac Measurement System) stenotic morphology, and angiographic response; including changes in minimum lumen diameter. Saphenous bypass graft angioplasty utilized larger balloons (CABG, 3.27 +/- 0.65 vs. native, 2.90 +/- 0.37 mm, P < .05), and higher inflation pressures (CABG, 10.1 +/- 3.7 vs. native, 8.8 +/- 2.5 atm, P < .05), although in a relative sense, balloon/artery ratios were similar (CABG, 1.09 +/- 0.20 vs. native, 1.03 +/- 0.15, pNS). Pre-procedural bypass graft lesions were more complex, with more frequent ACC/AHA type B1 lesions [CABG, 24/54 (44%) vs. native, 16/54 (30%), P < .05] and luminal thrombus [CABG, 17/54 (31%) vs. native, 6/54 (11%), P < .05]. Quantitative angiography revealed larger "reference" diameters within saphenous veins (CABG, 3.41 +/- 0.76 vs. native, 3.04 +/- 0.51 mm, P < .05), although minimum lumen diameter was less severe (CABG, 0.83 +/- 0.41 vs. native, 0.77 +/- 0.36, P < .05). In terms of balloon angioplasty response, greater improvement in luminal diameter was seen in bypass graft lesions (CABG, 1.55 +/- 0.53 vs. native, 1.32 +/- 0.44 mm, P < .05), with the largest changes within the "body" of the saphenous vein (ostial, 1.53 +/- 0.37; body, 1.68 +/- 0.50; anastomosis, 1.37 +/- 0.57 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Comparative analysis of saphenous vein bypass vs. native coronary artery balloon angioplasty: technical differences and angiographic response.
Cathet Cardiovasc Diagn. 1995 Apr;34(4):293-9; discussion 300. doi: 10.1002/ccd.1810340204.
2
Clinical and angiographic results of transluminal extraction coronary atherectomy in saphenous vein bypass grafts.隐静脉搭桥术中腔内抽吸取栓冠状动脉斑块旋切术的临床及血管造影结果
Circulation. 1994 Jan;89(1):302-12. doi: 10.1161/01.cir.89.1.302.
3
Retrieval of occluding unexpanded Palmaz-Schatz stent from a saphenous aorto-coronary vein graft.
Cathet Cardiovasc Diagn. 1995 Feb;34(2):159-61. doi: 10.1002/ccd.1810340418.
4
Influence of procedural success on immediate and long-term clinical outcome of patients undergoing percutaneous revascularization of occluded coronary artery bypass vein grafts.手术成功对接受冠状动脉搭桥静脉移植血管闭塞经皮血管重建术患者近期和长期临床结局的影响。
J Am Coll Cardiol. 1996 Dec;28(7):1732-7. doi: 10.1016/s0735-1097(96)00414-7.
5
Dual guiding catheters for saphenous venous graft protection during native coronary angioplasty.在原位冠状动脉血管成形术期间用于保护隐静脉移植物的双引导导管
Cathet Cardiovasc Diagn. 1995 Mar;34(3):255-8. doi: 10.1002/ccd.1810340119.
6
Influence of expanded balloon diameter on Palmaz-Schatz stent recoil.扩张球囊直径对帕尔马兹-沙茨支架回缩的影响。
Cathet Cardiovasc Diagn. 1995 Sep;36(1):11-6. doi: 10.1002/ccd.1810360105.
7
Implantation of half Palmaz-Schatz stents in short aorto-ostial lesions of saphenous vein grafts.
Cathet Cardiovasc Diagn. 1993 Jun;29(2):141-3. doi: 10.1002/ccd.1810290211.
8
[Percutaneous, transluminal angioplasty of aortocoronary venous bypass grafts--acute success, angiography and clinical follow-up].
Z Kardiol. 1991 Mar;80(3):215-21.
9
Excimer laser angioplasty vs. balloon angioplasty in saphenous vein bypass grafts: quantitative angiographic comparison of matched lesions.准分子激光血管成形术与球囊血管成形术治疗大隐静脉旁路移植血管病变的对比:配对病变的定量血管造影比较
Cathet Cardiovasc Diagn. 1996 Jun;38(2):153-8. doi: 10.1002/(SICI)1097-0304(199606)38:2<153::AID-CCD7>3.0.CO;2-8.
10
Comparison of percutaneous coronary intervention in native coronary arteries vs. bypass grafts in patients with prior coronary artery bypass graft surgery.既往接受冠状动脉旁路移植术患者的自身冠状动脉与旁路移植血管行经皮冠状动脉介入治疗的比较。
Cardiovasc Revasc Med. 2009 Apr-Jun;10(2):103-9. doi: 10.1016/j.carrev.2008.12.002.