A specific assay for the quantitative determination of the new antibiotic azithromycin in a low volume of human serum is described. The assay uses on-line high-performance liquid chromatography (HPLC) and atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI). Deuterium-labeled azithromycin was synthesized and used as the internal standard of the assay. The drug and the internal standard are extracted from 50 microliters of serum, and aliquots are injected onto a standard reverse-phase HPLC column. The effluent from the HPLC column at 1 ml/min is introduced into the atmospheric pressure source of a SCIEX API III mass spectrometer. Azithromycin concentrations in serum are determined by the selected monitoring of the protonated molecular ions of the drug and the internal standard. Our assay yields accurate and precise results over the range 10 ng/ml to 250 ng/ml. The correlation between the assay and a standard HPLC-electrochemical method, requiring a larger volume of serum, has been determined. The two methods showed excellent agreement. Because of its low volume requirement, our HPLC-APCI assay can be substituted for the standard assay for the investigation of azithromycin pharmacokinetics in children.
本文描述了一种用于定量测定少量人血清中新型抗生素阿奇霉素的特定分析方法。该分析方法采用在线高效液相色谱(HPLC)和大气压化学电离质谱(HPLC-APCI)。合成了氘代阿奇霉素并用作该分析方法的内标。药物和内标从50微升血清中提取,取 aliquots 注入标准反相HPLC柱。以1毫升/分钟的流速从HPLC柱流出的洗脱液被引入SCIEX API III质谱仪的大气压源中。通过对药物和内标的质子化分子离子进行选择监测来测定血清中阿奇霉素的浓度。我们的分析方法在10纳克/毫升至250纳克/毫升的范围内产生准确且精确的结果。已确定该分析方法与需要更大血清体积的标准HPLC-电化学方法之间的相关性。两种方法显示出极好的一致性。由于其对血清体积要求低,我们的HPLC-APCI分析方法可替代标准分析方法用于儿童阿奇霉素药代动力学研究。