• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Effects of different sampling methods for measurement of post dialysis blood urea nitrogen on urea kinetic modeling derived parameters in patients undergoing long-term hemodialysis.

作者信息

Lai Y H, Guh J Y, Chen H C, Tsai J H

机构信息

Division of Nephrology, Kaohsiung Medical College, Taiwan.

出版信息

ASAIO J. 1995 Apr-Jun;41(2):211-5.

PMID:7640430
Abstract

A simple and reliable sampling method for measuring post-dialysis blood urea nitrogen (C2) has not been well established. Therefore, the effects of different methods of sampling C2 on calculating urea kinetic modeling (UKM) derived parameters were studied in patients on hemodialysis. At first, C2 values were sampled at the end of hemodialysis at a blood flow rate of 300 ml per min (blood flow rate (Qb) 300 ml per min). They were then divided into two groups. In group 1 (n = 11), C2 samples were taken after slowing down Qb to 100 ml per min for 3 min (C2-100); the blood pump was then stopped for 1 min, and C2 was again sampled (C2-100-stop). Finally, C2 was sampled with Qb restored to 100 ml per min and the venous line clamped for another 12 sec (C2-100-clamp). In group 2 (n = 11), C2 samples were collected after Qb was slowed down to 50 ml per min for 3 min (C2-50), and C2-50-stop was then measured. Finally, C2-50-clamp was measured. Using C2-clamp as a reference standard, UKM parameters were calculated using a variable volume, single pool UKM. The authors found that Kt/V calculated by C2-300, C2-100, and C2-50 overestimated the reference Kt/V by 8.4-9.1%, 5.1%, and 3%, respectively. In contrast, protein catabolic rate and time-averaged BUN were affected only minimally. Therefore, a low flow technique with a Qb of 50 ml per min for 3 min can be used for the routine estimation of C2 and UKM-derived parameters with reasonable accuracy.

摘要

相似文献

1
Effects of different sampling methods for measurement of post dialysis blood urea nitrogen on urea kinetic modeling derived parameters in patients undergoing long-term hemodialysis.
ASAIO J. 1995 Apr-Jun;41(2):211-5.
2
Urea kinetics during sustained low-efficiency dialysis in critically ill patients requiring renal replacement therapy.需要肾脏替代治疗的危重症患者持续低效透析期间的尿素动力学
Am J Kidney Dis. 2002 Mar;39(3):556-70. doi: 10.1053/ajkd.2002.31406.
3
Mathematical analysis of urea rebound in long-term hemodialysis patients.长期血液透析患者尿素反弹的数学分析
Ther Apher Dial. 2005 Apr;9(2):167-72. doi: 10.1111/j.1774-9987.2005.00231.x.
4
In vivo effects of dialysate flow rate on Kt/V in maintenance hemodialysis patients.透析液流速对维持性血液透析患者Kt/V的体内效应。
Am J Kidney Dis. 2000 Jan;35(1):105-11. doi: 10.1016/S0272-6386(00)70308-8.
5
Influence of dialyser clearance measurement accuracy on haemodialysis prescription based on Kt/V.
Nephrol Dial Transplant. 1994;9(7):753-7.
6
A comparison of methods for determining urea distribution volume for routine use in on-line monitoring of haemodialysis adequacy.用于在线监测血液透析充分性的常规尿素分布容积测定方法的比较。
Nephrol Dial Transplant. 2009 Jan;24(1):211-6. doi: 10.1093/ndt/gfn457. Epub 2008 Aug 12.
7
Blood urea levels 30 minutes before the end of dialysis are equivalent to equilibrated blood urea.透析结束前30分钟的血尿素水平等同于平衡血尿素。
ASAIO J. 1997 Sep-Oct;43(5):M759-62.
8
[Urea distribution volume and ionic dialysance].[尿素分布容积与离子透析率]
G Ital Nefrol. 2004 Nov-Dec;21 Suppl 30:S226-30.
9
Reconciliation between urea kinetics and direct dialysis quantification.尿素动力学与直接透析定量之间的核对
Nephrol Dial Transplant. 1992;7(10):1007-12.
10
A regional blood circulation alternative to in-series two compartment urea kinetic modeling.串联双室尿素动力学模型的一种区域血液循环替代方案。
ASAIO J. 1993 Jul-Sep;39(3):M573-7.