Buscombe J R, Oyen W J, Corstens F H, Ell P J, Miller R F
Institute of Nuclear Medicine, University College London Medical School, UK.
Nucl Med Commun. 1995 May;16(5):327-35. doi: 10.1097/00006231-199505000-00003.
Prospectively, we compared the results of chest radiology and functional imaging, using 111In-labelled polyclonal human IgG (111In-HIG), in the identification of pulmonary infection in patients infected by the human immunodeficiency virus (HIV). Sixty-three studies were performed on 57 HIV-infected patients presenting with suspected chest infection or fever of unknown cause, in each of whom a planar chest radiograph was obtained within 24 h of the 111In-HIG study. The results of the two imaging modalities were compared with the final microbiological or cytological diagnosis. Forty patients were found to have pulmonary infection, 25 of whom were correctly identified with chest radiology (sensitivity 62%) and 39 with 111In-HIG (sensitivity 97%). In those patients without infection, chest radiology was abnormal in 13 cases (specificity 43%), while there was only one false-positive 111In-HIG study (specificity 95%). 111In-HIG correctly identified the presence or absence of active lung infection in 61 of 63 cases (accuracy 93%). This was significantly better (chi 2 = 8.25, upsilon = 1, P < 0.01) than chest radiology, which correctly identified the presence or absence of infection in 35 of 63 cases (accuracy 55%). In HIV antibody-positive patients, functional imaging with 111In-HIG is more accurate than chest X-ray in the identification of pulmonary infection.
前瞻性地,我们比较了使用铟-111标记的多克隆人免疫球蛋白G(111In-HIG)进行胸部放射学和功能成像在识别感染人类免疫缺陷病毒(HIV)患者肺部感染方面的结果。对57例疑似胸部感染或不明原因发热的HIV感染患者进行了63项研究,在每项研究中,在111In-HIG检查后24小时内获取了胸部平片。将两种成像方式的结果与最终的微生物学或细胞学诊断进行比较。发现40例患者有肺部感染,其中25例通过胸部放射学正确识别(敏感性62%),39例通过111In-HIG正确识别(敏感性97%)。在那些没有感染的患者中,胸部放射学有13例异常(特异性43%),而111In-HIG检查只有1例假阳性(特异性95%)。111In-HIG在63例中的61例中正确识别了是否存在活动性肺部感染(准确性93%)。这明显优于胸部放射学,胸部放射学在63例中的35例中正确识别了是否存在感染(准确性55%)(卡方=8.25,自由度=1,P<0.01)。在HIV抗体阳性患者中,使用111In-HIG进行功能成像在识别肺部感染方面比胸部X线更准确。