Gantz B J, Tyler R S, Woodworth G
Department of Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, USA.
Ann Otol Rhinol Laryngol Suppl. 1995 Sep;166:268-9.
A clinical trial of three different multichannel cochlear implants is in progress at The University of Iowa. Fifty postlingually deaf adults participated in a prospective randomized study of the Nucleus implant and the Ineraid device. Subsequently, 23 consecutive postlingually deaf adults have been implanted with the Clarion system. The speech perception performance obtained after 9 months of implant use with all devices was compared. In addition, Clarion patient results at 9 months were compared with long-term (36 months) results from subjects using the other two multichannel implants. Preliminary speech perception scores on the Iowa sentence test (sound-only) and NU-6 words (sound-only) demonstrate that the Clarion subjects, as a group, perform at higher levels than subjects using the other two systems. A wide range of performance is observed with all devices. The continuous interleaved pulsatile strategy of the Clarion device appears to be advantageous for this group of subjects.
爱荷华大学正在进行一项针对三种不同多通道人工耳蜗的临床试验。50名语后聋成年人参与了一项关于Nucleus植入物和Ineraid设备的前瞻性随机研究。随后,23名连续的语后聋成年人植入了Clarion系统。比较了所有设备使用植入物9个月后获得的言语感知性能。此外,还将Clarion患者9个月时的结果与使用其他两种多通道植入物的受试者的长期(36个月)结果进行了比较。爱荷华句子测试(仅声音)和NU - 6单词(仅声音)的初步言语感知分数表明,作为一个群体而言,Clarion受试者的表现高于使用其他两种系统的受试者。所有设备都观察到了广泛的性能范围。Clarion设备的连续交错脉冲策略似乎对这组受试者有利。