Effects of infusing pentafraction (Pen), a synthetic hydroxyethyl starch plasma volume expander, on lung and soft tissue lymph flux were compared in nonanesthetized sheep that were protein depleted by batch plasmapheresis. Pen (5%) was infused to raise pulmonary arterial wedge pressure by 5 mmHg for 2 h (1.8 +/- 0.3 l). Pen raised plasma osmotic pressure from plasmapheresis baseline (10.7 +/- 2.2 mmHg; preplasmapheresis baseline, 19.6 +/- 0.6 mmHg) to 16.6 +/- 2.4 mmHg. After Pen, lung lymph flows peaked at 3.9 +/- 2.0 times a preplasmapheresis baseline value of 1.0 (plasmapheresis baseline, 2.7 +/- 0.7), but soft tissue lymph flows rose insignificantly. Plasma Pen concentrations were 2.3 +/- 1.0% postinfusion and 1.6 +/- 0.3% at 12 h. Pen mean molecular masses at these times, measured by high-performance liquid chromatography, were 160 +/- 44 and 129 +/- 23 kDa, respectively. In lung lymph, Pen concentrations were 0.8 +/- 0.6% postinfusion and 0.7 +/- 0.2% at 12 h, with mean molecular masses of 125 +/- 44 and 112 +/- 18 kDa, respectively. In soft tissue lymph Pen was nearly undetectable postinfusion, but at 12 h concentrations averaged 0.3 +/- 0.2% with a mean molecular mass of 80 +/- 10 kDa. The osmotic effectiveness of Pen may be related to its molecular mass, which was large enough to restrict filtration so that the plasma-to-lung lymph osmotic pressure gradient widened. Pen remained effective in the circulation for at least 24 h.
在通过批量血浆置换使蛋白质缺乏的未麻醉绵羊中,比较了输注合成羟乙基淀粉血浆容量扩充剂五聚糖(Pen)对肺和软组织淋巴流量的影响。输注5%的Pen使肺动脉楔压升高5 mmHg,持续2小时(1.8±0.3升)。Pen使血浆渗透压从血浆置换基线(10.7±2.2 mmHg;血浆置换前基线,19.6±0.6 mmHg)升至16.6±2.4 mmHg。输注Pen后,肺淋巴流量峰值达到血浆置换前基线值1.0的3.9±2.0倍(血浆置换基线,2.7±0.7),但软组织淋巴流量升高不明显。输注后血浆Pen浓度为2.3±1.0%,12小时时为1.6±0.3%。通过高效液相色谱法测得此时Pen的平均分子量分别为160±44 kDa和129±23 kDa。在肺淋巴中,输注后Pen浓度为0.8±0.6%,12小时时为0.7±0.2%,平均分子量分别为125±44 kDa和112±18 kDa。在软组织淋巴中,输注后Pen几乎检测不到,但12小时时浓度平均为0.3±0.2%,平均分子量为80±10 kDa。Pen的渗透效力可能与其分子量有关,其分子量足够大以限制滤过,从而使血浆至肺淋巴的渗透压梯度变宽。Pen在循环中至少24小时保持有效。