Irie T, Suzuki S, Yamauchi T, Kusano S
Department of Radiology, National Defense Medical College, Saitama, Japan.
Acta Radiol. 1995 Mar;36(2):154-8.
A technique for the prediction of the time to peak hepatic enhancement to optimize contrast-enhanced spiral CT has been developed. The procedures are (a) to inject a small amount of contrast medium rapidly via the antecubital vein and measure aortic transit time (ATT) of the bolus by single slice dynamic CT; (b) to inject contrast medium at a high rate, expecting peak hepatic enhancement to occur at ATT plus 8 seconds after the end of injection; (c) to perform spiral scanning of the liver using thin collimation and caudo-cranial table movement beginning at ATT after the end of contrast medium injection.