Zhongguo Yao Li Xue Bao. 1994 Sep;15(5):458-61.
Tretinoin (Tre) and its active stereo isomer isotretinoin (Iso) were simultaneously determined by reversed-phase high pressure liquid chromatographic method with a uv detector adjusted to 348 nm. Separation was accomplished on YWG-C18 column by using a MeOH:NH4Ac buffer (pH 6.0) 85:15 (vol:vol), chlorpromazine (Chl) being chosen as internal standard. Minimal detectable amount of Tre was 0.5 ng. Calibration curve was linear (r = 0.9999) in the concentration range of 25-2500 ng.ml-1. This method was used to determinate the transdermal amounts of Tre from three different preparations in Franz diffusion cell in vitro. The results showed that the proposed method could distinguish the transdermal differences from various formulations or different skin samples. In addition, it is able to be used in quantitative analysis of Tre and Iso.
采用反相高效液相色谱法,使用紫外检测器(检测波长为348nm)同时测定维甲酸(Tre)及其活性立体异构体异维甲酸(Iso)。在YWG-C18柱上,以甲醇:醋酸铵缓冲液(pH 6.0)85:15(体积比)为流动相,选用氯丙嗪(Chl)作为内标进行分离。维甲酸的最低检测量为0.5ng。在25 - 2500ng·ml-1浓度范围内校准曲线呈线性(r = 0.9999)。该方法用于体外测定Franz扩散池中三种不同制剂的维甲酸透皮量。结果表明,所提出的方法能够区分不同制剂或不同皮肤样品的透皮差异。此外,它可用于维甲酸和异维甲酸的定量分析。