Suppr超能文献

Quantification of recruitable coronary collateral blood flow in conscious humans and its potential to predict future ischemic events.

作者信息

Pijls N H, Bech G J, el Gamal M I, Bonnier H J, De Bruyne B, Van Gelder B, Michels H R, Koolen J J

机构信息

Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands.

出版信息

J Am Coll Cardiol. 1995 Jun;25(7):1522-8. doi: 10.1016/0735-1097(95)00111-g.

Abstract

OBJECTIVES

The present study was designed to evaluate the applicability of a pressure-flow equation for quantitative calculation of recruitable collateral blood flow at coronary artery occlusion in conscious patients and to investigate the value of that index to predict future ischemic events.

BACKGROUND

Recent experimental studies have indicated that recruitable collateral blood flow at coronary artery occlusion can be expressed as a fraction of normal maximal myocardial blood flow by simultaneous recordings of mean arterial, coronary wedge and central venous pressures, respectively. This index is called the pressure-derived fractional collateral flow and is independent of hemodynamic loading conditions.

METHODS

In 120 patients undergoing elective coronary angioplasty, mean arterial, coronary wedge and central venous pressures were measured at balloon inflations of 2 min. All patients had a recent exercise electrocardiogram (ECG) with positive findings showing clearly distinguishable, reversible ECG abnormalities, enabling recognition of ischemia at balloon inflation. Fractional collateral blood flow at angioplasty was calculated by coronary wedge pressure minus central venous pressure divided by mean arterial pressure minus central venous pressure and correlated to the presence or absence of ischemia at balloon inflation. Ischemic events were monitored during a follow-up period of 6 to 22 months.

RESULTS

In 90 of the 120 patients, ischemia was present at balloon inflation, and in 82 of these patients, fractional collateral blood flow was < or = 23%. By contrast, in 29 patients, no ischemia was present, and fractional collateral blood flow was > 24% in all 29. During the follow-up period, 16 patients had an ischemic event. Fifteen of these 16 patients were in the group with insufficient collateral flow (p < 0.05).

CONCLUSIONS

To our knowledge, this study presents the first method for quantitative assessment of recruitable collateral blood flow in humans in the catheterization laboratory. Sufficient and insufficient collateral circulation can be reliably distinguished by this method. Use of this method can also help to provide more insight into the extent and behavior of the collateral circulation for investigational purposes and may have potential clinical implications.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验