We report a simple technique for obtaining H-reflexes from the extensor carpi radialis (ECR) muscle. In 50 normal test subjects, above-elbow stimulation of the radial nerve evoked ECR H-reflexes, in all 100 arms with facilitation, and in only 8 without facilitation. H-waves were less common in extensor digitorum communis and rare in brachioradialis; these could have been volume-conducted ECR responses. Median-nerve stimulation at the elbow evoked H-reflexes in 92 of the 100 flexor carpi radialis (FCR) muscles; 44 of these required no facilitation. Background EMG (facilitation) activity or an overlapping M-wave often obscured the H-wave onset: among the onsets considered reliable in FCR (67/92) and ECR (84/100), mean latencies were 16.2 msec and 16.5 msec respectively, and correlated well with subject height and arm length. There was no significant difference in latency obtained with and without facilitation for the FCR H-reflexes and between techniques for the ECR H-reflexes. Right-left differences in latency ranged from 0 to 0.9 msec for ECR and 0 to 0.6 msec for FCR H-reflexes.
我们报告了一种从桡侧腕伸肌(ECR)获取H反射的简单技术。在50名正常测试对象中,对桡神经进行肘部以上刺激时,在所有100条手臂中均诱发出了有易化作用的ECR H反射,只有8条手臂没有易化作用。H波在指总伸肌中较少见,在肱桡肌中罕见;这些可能是ECR反应的容积传导。在肘部对正中神经进行刺激时,100条桡侧腕屈肌(FCR)中有92条诱发出了H反射;其中44条不需要易化。背景肌电图(易化)活动或重叠的M波常常掩盖H波起始点:在FCR(67/92)和ECR(84/100)中被认为可靠的起始点中,平均潜伏期分别为16.2毫秒和16.5毫秒,并且与受试者身高和手臂长度密切相关。FCR H反射在有易化和没有易化时获得的潜伏期以及ECR H反射的不同技术之间没有显著差异。ECR H反射潜伏期的左右差异范围为0至0.9毫秒,FCR H反射为0至0.6毫秒。