A method of optimizing the geometrical and electrical parameters of multielectrodes implanted in the brain is presented. The method should be valuable for the standardization of the implantation procedure. It bases on numerical solutions of the partial differential equations governing the electric potential. A description of the computer program developed is given, results pertaining to special cases are included, as well as other possible applications.
本文提出了一种优化植入大脑的多电极几何和电学参数的方法。该方法对于植入程序的标准化具有重要价值。它基于控制电势的偏微分方程的数值解。文中给出了所开发计算机程序的描述,包括特殊情况的结果以及其他可能的应用。