Leonard B E
International Academy of Hi-Tech Services, Inc., Annapolis, MD 21403, USA.
Health Phys. 1995 Jul;69(1):75-92. doi: 10.1097/00004032-199507000-00008.
The radiological hazard of radon gas to occupants in residential environments is from the particulate progeny 218Po, 214Pb, 214Bi, and 214Po, rather than 222Rn itself. Attachment to aerosols, plateout, and resuspension impact on the progeny airborne concentrations. Plateout rate and resuspension factors were measured for air change (ventilation) rates, 0.01 to 1.0 h-1, in a 0.28 m3 test chamber for interior residential materials of wallboard, drapery, carpet, ceiling tile, and concrete, and from 0.05 to 2.5 h-i for hardwood and glass. The overall accuracy of the plateout rate values is estimated to be +/- 13% standard deviation. For the different materials, the plateout rates for 218Po progeny varied by a factor of nearly six. Drapery gave the largest plateout rates. Resuspension rate factors, R, were measured for hardwood, wallboard, drapery, carpet, and glass by a new time-dependent measurement method based on the difference in buildup rate of 214Po to equilibrium caused by resuspension. Values for R obtained for hardwood, wallboard, drapery, carpet and glass were 0.31, 0.29, 0.44, 0.55, and 0.36, respectively ( +/- 30% standard deviation). All measurements were made in a continuous air conditioned interior environment maintaining temperature at 22.2 +/- 1.1 degrees C and relative humidity of 30% +/- 10%. Computations were made of equivalent plateout rates and equilibrium fractions for a standard 5 m x 5 m x 3 m high room to provide values to compare with other work.
在居住环境中,氡气对居住者的辐射危害来自于其放射性子体218Po、214Pb、214Bi和214Po,而非222Rn本身。气溶胶附着、沉降和再悬浮会影响子体在空气中的浓度。在一个0.28立方米的测试舱中,针对换气(通风)率为0.01至1.0 h-1的情况,测量了墙板、窗帘、地毯、天花板瓷砖和混凝土等室内居住材料的沉降率和再悬浮因子;对于硬木和玻璃,换气率范围为0.05至2.5 h-1。沉降率值的总体精度估计为标准偏差±13%。对于不同材料,218Po子体的沉降率相差近6倍。窗帘的沉降率最大。通过一种基于再悬浮导致的214Po积累速率差异的新的随时间变化的测量方法,测量了硬木、墙板、窗帘、地毯和玻璃的再悬浮率因子R。硬木、墙板、窗帘、地毯和玻璃的R值分别为0.31、0.29、0.44、0.55和0.36(标准偏差±30%)。所有测量均在温度保持在22.2±1.1摄氏度、相对湿度为30%±10%的连续空调室内环境中进行。针对一个标准的5米×5米×3米高的房间,计算了等效沉降率和平衡分数,以提供与其他研究结果进行比较的值。