Suppr超能文献

用于显微神经外科手术的照明镜

Lighted mirror for microneurosurgery.

作者信息

Seki Y, Takada K, Tsuchida S, Teramoto A

机构信息

Department of Neurosurgery, Toranomon Hospital, Tokyo, Japan.

出版信息

Surg Neurol. 1995 Apr;43(4):395-7. doi: 10.1016/0090-3019(95)80071-n.

Abstract

We describe a newly developed, lighted mirror that provides enough luminous intensity to obtain a clear image in deep operative fields under high magnification. Through the initial neurosurgical procedures in which it was tested, the mirror proved particularly useful for inspecting the ventral aspect of the fifth nerve in a microvascular decompression for trigeminal neuralgia, and for observing the fundus of the internal auditory meatus after removal of an acoustic neuroma to ensure no residual tumor.

摘要

我们描述了一种新开发的带光源镜子,其提供足够的发光强度,以便在高倍放大下的深部手术视野中获得清晰图像。在对其进行测试的最初神经外科手术中,该镜子被证明特别适用于在三叉神经痛微血管减压术中检查第五神经的腹侧,以及在切除听神经瘤后观察内耳道底部以确保无残留肿瘤。