Suppr超能文献

右侧高位输尿管钝性创伤破裂,采用阑尾置入修复。

Blunt traumatic rupture of the high right ureter, repaired with appendix interposition.

作者信息

Fernandez Fernandez A, Soria Ruiz S, Gomez Martinez I, Gil Fabra J, Martinez Castellaños F, Otero Mauricio G

机构信息

Department of Urology of the Hospital, San Millan, San Pedro, La Rioja, Spain.

出版信息

Urol Int. 1994;53(2):97-8. doi: 10.1159/000282644.

Abstract

We report the first case of upper lumbar ureteral replacement with the vermiform appendix, in a blunt traumatic ureter rupture with important urinoma. In selected cases, in which the appendix has a required caliber and length, the vermiform appendix is a very good autograft for ureteral substitution. The vermiform appendix must be preserved if possible in the abdominal surgery.

摘要

我们报告了首例用阑尾替代上腰椎段输尿管的病例,该病例为钝性创伤性输尿管破裂并伴有大量尿外渗。在某些特定病例中,若阑尾具备所需的管径和长度,阑尾是输尿管替代的一种非常好的自体移植物。在腹部手术中,应尽可能保留阑尾。