Suppr超能文献

Comparison of clinical and angiographic outcomes after saphenous vein graft angioplasty using coronary versus 'biliary' tubular slotted stents.

作者信息

Wong S C, Popma J J, Pichard A D, Kent K M, Satler L F, Mintz G S, Chuang Y C, Hong M K, Ditrano C J, Leon M B

机构信息

Department of Internal Medicine (Division of Cardiology), Washington Hospital Center, Washington, DC 20010.

出版信息

Circulation. 1995 Jan 15;91(2):339-50. doi: 10.1161/01.cir.91.2.339.

Abstract

BACKGROUND

Saphenous vein graft (SVG) angioplasty using 15-mm articulated, tubular slotted stents results in low (0% to 20%) residual diameter stenoses and infrequent (< 5%) major complications. A "biliary" stent design with greater radial compressive strength, enhanced visibility, and more variable sizing (diameter and length) has been approved for noncoronary indications. A comparison of outcomes after coronary versus biliary stent placement in SVG stenoses has not been performed. The purpose of this study was to compare the angiographic and clinical results after SVG angioplasty using these two balloon-expandable, tubular slotted stent designs.

METHODS AND RESULTS

During a 3-year period, 231 patients with 305 SVG lesions were treated using Palmaz-Schatz coronary (n = 108) or biliary (n = 123) stents. Cineangiograms were reviewed using qualitative morphological and quantitative angiographic methods. Time-dependent clinical outcome (freedom from death, Q-wave myocardial infarction, or the need for repeat coronary bypass surgery or SVG angioplasty) was assessed using Kaplan-Meier life-table methods. Unstable angina (P < .001) and recent myocardial infarction (P = .001) were present more often in patients undergoing biliary stent versus coronary stent placement. Biliary stent-treated SVG lesions were more frequently de novo (P = .001), ostial in location (P = .002), > or = 10 mm in length (P = .009), thrombus containing (P = .001), and ulcerated (P < .001) than coronary stent-treated SVG lesions. Angiographically, biliary stent-treated lesions had larger reference vessel diameter (3.43 +/- 0.59 mm versus 3.10 +/- 0.64 mm, P < .001), higher balloon-to-artery ratio (1.15 +/- 0.16 mm versus 1.07 +/- 0.19, P = .0001), and lower residual diameter stenosis (6 +/- 17% versus 14 +/- 11% in coronary stent-treated patients; P < .001). Procedural success rates were high (95%), in-hospital major complications were uncommon (< 3%), and follow-up clinical outcomes were favorable (6-month event-free survival approximately 80%) in both groups.

CONCLUSIONS

Despite frequent short-term ischemic syndromes and unfavorable lesion characteristics, both biliary and coronary cohorts have similarly favorable short-term procedural results and long-term clinical outcomes. The increased strut thickness of the biliary stent confers greater fluoroscopic visibility and radial compressive strength in exchange for decreased stent flexibility and added technical demand in stent deployment. Extreme caution is recommended with biliary stent placement in the treatment of SVG lesions as clinical results are highly operator dependent.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验