Suppr超能文献

视觉判定的高频癫痫发作活动。

Visually determined high-frequency seizure activity.

作者信息

Swartz C M, Abrams R, Rasmussen K, Zorumski C F

机构信息

Department of Psychiatric Medicine, East Carolina University School of Medicine, Greenville, North Carolina 27858-4354.

出版信息

Convuls Ther. 1994 Sep;10(3):224-7.

PMID:7834260
Abstract

The duration of high-frequency electroconvulsive therapy (ECT) seizure activity, the "spike seizure duration," was rated by two experienced clinicians from the paper EEG recording, along with total EEG seizure duration. The spike seizure duration, taken together with other seizure duration measurements, has shown differences between ECT methods of apparently different efficacy, such as unilateral and bilateral ECT. Close correspondence between the raters demonstrated high reliability for the determination of spike seizure duration, with interrater reliability kappa of 0.92 (p < 10(-6), although the raters employed different rules for selecting the end point.

摘要

高频电休克治疗(ECT)发作活动的持续时间,即“尖峰发作持续时间”,由两名经验丰富的临床医生根据纸质脑电图记录进行评定,同时评定脑电图发作总持续时间。尖峰发作持续时间与其他发作持续时间测量结果相结合,已显示出明显不同疗效的ECT方法之间存在差异,如单侧和双侧ECT。评分者之间的密切一致性表明,尖峰发作持续时间的测定具有很高的可靠性,评分者间信度kappa为0.92(p < 10⁻⁶),尽管评分者采用了不同的规则来选择终点。