Sato Y, Santos-Sacchi J
Department of Otolaryngology, Kawasaki Medical School, Japan.
Hear Res. 1994 Oct;80(1):21-4. doi: 10.1016/0378-5955(94)90004-3.
The input capacitance of cell pairs or small groups can be used to gauge the degree of electrical coupling via gap junctions (Santos-Sacchi, 1991). In order to estimate junctional sensitivity to intracellular Ca+2 and H+ concentration, the input capacitance of supporting cell syncytia of the organ of Corti was measured with the whole cell voltage clamp technique, while directly modifying the cation concentrations via the patch pipette. Typically, a pH below 6.5 was capable of uncoupling Hensen cells. On the other hand, pCa levels as low as 3 were ineffective.
细胞对或小细胞群的输入电容可用于衡量通过缝隙连接的电耦合程度(Santos-Sacchi,1991)。为了评估连接对细胞内Ca+2和H+浓度的敏感性,采用全细胞电压钳技术测量了柯蒂氏器支持细胞合体的输入电容,同时通过膜片吸管直接改变阳离子浓度。通常,pH值低于6.5能够使亨森细胞解偶联。另一方面,低至3的pCa水平无效。