Moroz I A, Serezhenkov V A, Klevezal' G A, Burbaev D Sh, Vanin A F
Biofizika. 1994 Nov-Dec;39(6):1075-81.
Spin-lattice relaxation rates of radiation induced and background centers in dental enamel have been investigated by electron spin resonance techniques. It has been found that these centers differ in the value of the saturation half-power and the saturation process. Based on these experimental results a new approach to discrimination of the radiation induced signal from the total ESR spectrum of dental enamel is proposed. Comparison of the current methods of radiation dose estimation by the ESR analysis has been performed using the new approach.
利用电子自旋共振技术研究了牙釉质中辐射诱导中心和本底中心的自旋-晶格弛豫率。发现这些中心在饱和半功率值和饱和过程方面存在差异。基于这些实验结果,提出了一种从牙釉质总电子自旋共振谱中区分辐射诱导信号的新方法。使用该新方法对当前通过电子自旋共振分析估算辐射剂量的方法进行了比较。