The refractive error after implantation of a posterior chamber intraocular lens. The accuracy of IOL power calculation in a hospital practice.

作者信息

Høvding G, Natvik C, Sletteberg O

机构信息

Department of Ophthalmology, University of Bergen, Norway.

出版信息

Acta Ophthalmol (Copenh). 1994 Oct;72(5):612-6. doi: 10.1111/j.1755-3768.1994.tb07188.x.

Abstract

The study included 188 patients, in which a posterior chamber intraocular lens was implanted after extracapsular cataract extraction. After modifications of the intraocular lens constants (SRK formula and SRK II formula) and correction of the axial length measurements (Colenbrander-Hoffer formula) had been made, the mean differences between the actual postoperative spherical equivalent and that predicted by the three formulas were -0.23D, -0.22D and -0.46D, respectively. More than +/-1.0D deviation from the predicted postoperative refraction occurred in about one-third of the cases. Inter-observed discrepancy regarding the accuracy of the preoperative measurement of the ocular axis length is suggested to be the main cause of unpredicted postoperative refractive errors.

摘要

该研究纳入了188例患者,这些患者在白内障囊外摘除术后植入了后房型人工晶状体。在对人工晶状体常数(SRK公式和SRK II公式)进行修正以及对眼轴长度测量值(科伦布兰德-霍弗公式)进行校正后,实际术后等效球镜度与三个公式预测值之间的平均差值分别为-0.23D、-0.22D和-0.46D。约三分之一的病例术后屈光与预测值的偏差超过±1.0D。术前眼轴长度测量准确性方面观察到的差异被认为是术后屈光误差不可预测的主要原因。