Densitometric properties of long bones in dogs, as determined by use of dual-energy x-ray absorptiometry.

作者信息

Markel M D, Sielman E, Bodganske J J

机构信息

Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin-Madison 53706.

出版信息

Am J Vet Res. 1994 Dec;55(12):1750-6.

PMID:7887522
Abstract

We performed dual-energy x-ray absorptiometry (craniocaudal and lateromedial views) on 10 pairs of humeruses, radiuses, femurs, and tibias from dogs, using an alignment jig, to determine the homotypic bone mineral density variations of long bones. The bones were divided into 3 regions: proximal, middle, and distal parts of the diaphysis. The bone mineral density of cortical bone, medullary bone, and total bone was determined. Of 160 homotypic comparisons, 21 indicated significant (P < or = 0.05) differences between right and left bones at either a region or location. These differences were observed most frequently in the craniocaudal view and were probably secondary to positioning errors. Evaluation of elliptical bones, such as the radius, also indicated that, when the thicker dimension, such as the lateromedial view of the radius was measured, the bone mineral density of regions-of-interest in that view was greater than that in the opposite view (ie, craniocaudal view of the radius). This study validates the concept of using the contralateral limb as the control condition in orthopedic studies of dogs, particularly when evaluating the densitometric properties of long bones. This study also emphasizes the importance of accurate positioning to prevent inadvertent alteration of bone mineral density results when using dual-energy x-ray absorptiometry. Dual-energy x-ray absorptiometry is particularly susceptible to positioning errors, because it converts a 3-dimensional structure into a 2-dimensional image.

摘要

我们使用校准夹具,对10对来自犬的肱骨、桡骨、股骨和胫骨进行双能X线吸收测定法(头尾位和内外侧位),以确定长骨的同型骨矿物质密度变化。将这些骨头分为3个区域:骨干的近端、中部和远端。测定皮质骨、髓质骨和全骨的骨矿物质密度。在160次同型比较中,有21次显示在某个区域或位置的左右骨骼之间存在显著(P≤0.05)差异。这些差异在头尾位观察中最常出现,可能是定位误差所致。对椭圆形骨骼(如桡骨)的评估还表明,当测量较厚维度(如桡骨的内外侧位)时,该视图中感兴趣区域的骨矿物质密度高于相反视图(即桡骨的头尾位)。本研究验证了在犬的骨科研究中使用对侧肢体作为对照条件的概念,特别是在评估长骨的密度测量特性时。本研究还强调了准确定位的重要性,以防止在使用双能X线吸收测定法时意外改变骨矿物质密度结果。双能X线吸收测定法特别容易受到定位误差的影响,因为它将三维结构转换为二维图像。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验