Suppr超能文献

Estimation of coronary flow reserve by transesophageal coronary sinus Doppler measurements in patients with syndrome X and patients with significant left coronary artery disease.

作者信息

Zehetgruber M, Mundigler G, Christ G, Mörtl D, Probst P, Baumgartner H, Maurer G, Siostrzonek P

机构信息

Department of Cardiology, University of Vienna, Austria.

出版信息

J Am Coll Cardiol. 1995 Apr;25(5):1039-45. doi: 10.1016/0735-1097(94)00544-z.

Abstract

OBJECTIVES

This study sought to determine the feasibility of coronary sinus flow velocity analysis by transesophageal Doppler echocardiography for estimation of coronary flow reserve in patients with syndrome X and patients with coronary artery disease.

BACKGROUND

Coronary flow reserve provides useful information in patients with coronary artery disease and patients with syndrome X. Current methods of measuring coronary flow reserve are invasive or require extensive laboratory equipment, or both. Transesophageal Doppler recordings of coronary sinus flow velocity before and after vasodilator application may allow noninvasive determination of coronary flow reserve.

METHODS

We obtained coronary sinus flow velocity recordings before and after dipyridamole administration (0.6 mg/kg body weight per 5 min) in 9 patients with syndrome X, 14 with significant left coronary artery disease and 22 age-matched control patients. We used the formula anterograde minus retrograde flow velocity time integral times heart rate as an index of coronary sinus flow. Coronary flow reserve was calculated by dividing coronary sinus flow variables after dipyridamole administration by the respective baseline values.

RESULTS

Technically adequate recordings were obtained in 44 (98%) of 45 patients. Compared with that in the control group (2.78 +/- 0.95 [mean +/- SD]), coronary flow reserve was significantly lower in patients with syndrome X (1.21 +/- 0.23, p < or = 0.001) as well as in those with coronary artery disease (1.47 +/- 0.7, p < or = 0.001). Using a cutoff coronary flow reserve value of 1.8, sensitivity, specificity and overall predictive value of coronary flow reserve determinations were, respectively, 100%, 91% and 94% for syndrome X and 86%, 91% and 89% for coronary artery disease.

CONCLUSIONS

Coronary flow reserve calculation by transesophageal coronary sinus flow velocity recordings is feasible in a large proportion of patients and might be useful for the noninvasive evaluation of patients with syndrome X and patients with severe left coronary artery disease.

摘要

相似文献

6
Coronary flow reserve assessment by dobutamine transesophageal Doppler echocardiography.
J Am Coll Cardiol. 1995 Feb;25(2):325-32. doi: 10.1016/0735-1097(94)00395-7.
7
Noninvasive evaluation of flow reserve in the left anterior descending coronary artery in patients with cardiac syndrome X.
Am J Cardiol. 2007 May 15;99(10):1378-83. doi: 10.1016/j.amjcard.2006.12.070. Epub 2007 Mar 28.
9
Coronary microcirculation evaluation with transesophageal echocardiography Doppler in type II diabetics.
Int J Cardiol. 1997 Apr 18;59(2):119-24. doi: 10.1016/s0167-5273(97)02935-5.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验