Suppr超能文献

左乳内动脉移植血管远端吻合口处支架置入术:一例报告

Stenting the distal anastomotic site of the left internal mammary artery graft: a case report.

作者信息

Hadjimiltiades S, Gourassas J, Louridas G, Tsifodimos D

机构信息

AHEPA General Hospital, University of Thessaloniki, Greece.

出版信息

Cathet Cardiovasc Diagn. 1994 Jun;32(2):157-61. doi: 10.1002/ccd.1810320211.

Abstract

The major problem associated with the long-term patency of the internal mammary artery graft is the early occurrence of stenosis usually at its distal anastomotic site; its management by balloon angioplasty has been associated with a high success rate. We report the case of an unsuccessful balloon angioplasty of an anastomotic stenosis of a left internal mammary artery graft that was successfully managed by stenting with one-half of a Palmaz-Schatz stent.

摘要

与乳内动脉移植物长期通畅相关的主要问题是早期狭窄的发生,通常在其远端吻合部位;通过球囊血管成形术对其进行治疗的成功率较高。我们报告了一例左乳内动脉移植物吻合口狭窄球囊血管成形术失败的病例,该病例通过植入半个Palmaz-Schatz支架成功治疗。