A comparative study between Gd-DTPA and oral magnetic particles (OMP) as gastrointestinal (GI) contrast agents for MRI of the abdomen.

作者信息

Vlahos L, Gouliamos A, Athanasopoulou A, Kotoulas G, Claus W, Hatziioannou A, Kalovidouris A, Papavasiliou C

机构信息

Department of Radiology, Areteion University Hospital, Athens, Greece.

出版信息

Magn Reson Imaging. 1994;12(5):719-26. doi: 10.1016/0730-725x(94)92196-2.

Abstract

In the present study we compared two gastrointestinal contrast agents--Gd-DTPA, a positive signal, and oral magnetic particles (OMP), a negative signal contrast agent--in patients who were referred for MR imaging of the abdomen. Altogether 60 patients were examined with the former and 28 patients with the latter contrast before and after the administration of contrast media. Gd-DTPA was given either per os or per rectum. In comparing the results, it was shown that the diagnostic accuracy of postcontrast MRI in both groups was more or less similar to CT but much higher as compared with plain MRI. In the OMP series, first the contrast between the GI-filled lumen and the surrounding fat was much superior to that of the Gd-DTPA and, second, there was no evidence of any artifacts from bowel motion. However, the overall accuracy of the Gd-DTPA group was better compared with that of the OMP group. This was due to underfilling of the distal bowel because the OMP in those patients was administered only per os. Finally, Gd-DTPA had a more pleasant taste and fewer side effects. It is concluded that both contrast media are suitable for the upper abdomen because the results are comparable, whereas for the lower abdomen Gd-DTPA is superior because it can be used from both routes.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验