Frau G N, Luxford W M, Lo W W, Berliner K I, Telischi F F
Gruppo Otologico, Piacenza, Italy.
J Laryngol Otol. 1994 Sep;108(9):743-8. doi: 10.1017/s0022215100128002.
High-resolution computed tomography (HRCT) is important in the evaluation of cochlear implant candidates. This study examines the accuracy of radiological assessment of cochlear patency in relation to findings at the time of surgery. Older and newer HRCT methods and attending and senior radiologist interpretations are compared in a large series of cochlear implant patients. Subjects were 50 adults (22 to 74 years) and 31 children (2.4 to 11.7 years) who received either a 3M/House or a Nucleus 22-channel cochlear implant. Attending radiologist reports were obtained by chart review and the scans were re-reviewed for this study by a senior radiologist. Accuracy in detecting cochlear ossification ranged from 86.4 per cent for attending radiologists, with all HRCT scans, to 94.7 per cent for the senior radiologist with newer HRCT scans. False positives were rare, but false negatives did occur. Overall, best results were obtained with newer HRCT scans and a senior radiologist. Knowledge of the presence and extent of cochlear ossification is important to the implant surgeon and for patient counselling. Technical guidelines and a check list for interpretation of results are presented.
高分辨率计算机断层扫描(HRCT)在评估人工耳蜗植入候选者时很重要。本研究探讨了与手术时的发现相关的耳蜗通畅性放射学评估的准确性。在一大系列人工耳蜗植入患者中,比较了较旧和较新的HRCT方法以及主治放射科医生和资深放射科医生的解读。研究对象为50名成年人(22至74岁)和31名儿童(2.4至11.7岁),他们接受了3M/豪斯或Nucleus 22通道人工耳蜗植入。通过查阅病历获取主治放射科医生的报告,本研究由一位资深放射科医生对扫描结果进行重新评估。检测耳蜗骨化的准确率,主治放射科医生对所有HRCT扫描结果的准确率为86.4%,资深放射科医生对较新HRCT扫描结果的准确率为94.7%。假阳性很少见,但假阴性确实存在。总体而言,使用较新的HRCT扫描和资深放射科医生能获得最佳结果。了解耳蜗骨化的存在和程度对植入外科医生和患者咨询很重要。文中给出了结果解读的技术指南和检查清单。