• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Accuracy of high-resolution computed tomography in cochlear implantation.

作者信息

Langman A W, Quigley S M

机构信息

Division of Otology, Neurotology & Skull Base Surgery, Virginia Mason Medical Center, Seattle, WA 98111, USA.

出版信息

Otolaryngol Head Neck Surg. 1996 Jan;114(1):38-43. doi: 10.1016/S0194-59989670281-4.

DOI:10.1016/S0194-59989670281-4
PMID:8570248
Abstract

Multichannel cochlear implants are a proven method for the auditory rehabilitation of individuals who have severe-to-profound sensorineural hearing loss. These devices typically require insertion into the scala tympani of the cochlea to provide auditory stimulations. A patent scala provides the best chance for an adequate insertion of the electrode array. Preoperative high-resolution computed tomography imaging has traditionally been used to determine the patency of the scala tympani. Its ability to accurately predict the patency of the cochlea has been questioned in several retrospective studies. A prospective study was undertaken in 28 consecutive individuals undergoing cochlear implant surgery to compare the findings on high-resolution computed tomography with the surgical findings in an attempt to determine high-resolution computed tomography's accuracy. Cochlear obstruction caused by ossification was accurately predicted in six of six individuals but overestimated in the round window region in three individuals. High-resolution computed tomography accurately predicted patent cochleas in 19 individuals. No false-negative results were encountered. In this study sensitivity of high-resolution computed tomography was 100%, and specificity was 86%. High-resolution computed tomography appears to be more helpful than previously reported for determining cochlear patency.

摘要

相似文献

1
Accuracy of high-resolution computed tomography in cochlear implantation.
Otolaryngol Head Neck Surg. 1996 Jan;114(1):38-43. doi: 10.1016/S0194-59989670281-4.
2
Systematic approach to electrode insertion in the ossified cochlea.在骨化耳蜗中进行电极插入的系统方法。
Otolaryngol Head Neck Surg. 1996 Jan;114(1):4-11. doi: 10.1016/S0194-59989670275-9.
3
Cochlear implants in children: reliability of computed tomography.
Otolaryngol Head Neck Surg. 1992 Sep;107(3):410-7. doi: 10.1177/019459989210700312.
4
Nucleus multichannel cochlear implantation in partially ossified cochleas using the Steenerson procedure.
Otol Neurotol. 2002 May;23(3):341-5. doi: 10.1097/00129492-200205000-00019.
5
Round window electrode insertion potentiates retention in the scala tympani.圆窗电极插入可增强鼓阶内的潴留。
Acta Otolaryngol. 2012 Sep;132(9):932-7. doi: 10.3109/00016489.2012.680493. Epub 2012 Jun 5.
6
Multichannel cochlear implantation in the scala vestibuli.前庭阶多通道人工耳蜗植入术。
Otol Neurotol. 2006 Aug;27(5):634-8. doi: 10.1097/01.mao.0000224095.63354.1a.
7
Scala vestibuli insertion in cochlear implantation: a valuable alternative for cases with obstructed scala tympani.耳蜗植入术中前庭阶插入:对于鼓阶阻塞病例的一种有价值的替代方法。
ORL J Otorhinolaryngol Relat Spec. 2000 Sep-Oct;62(5):251-6. doi: 10.1159/000027755.
8
Cochlear coiling pattern and orientation differences in cochlear implant candidates.人工耳蜗植入候选人的耳蜗卷曲模式和方向差异。
Otol Neurotol. 2011 Sep;32(7):1086-93. doi: 10.1097/MAO.0b013e31822a1ee2.
9
Cochlear patency problems in cochlear implantation.人工耳蜗植入中的耳蜗通畅性问题。
Laryngoscope. 1987 Jul;97(7 Pt 1):801-5.
10
Evaluation of cochlear implant electrode position after a modified round window insertion by means of a 64-multislice CT.通过64层螺旋CT评估改良圆窗插入后人工耳蜗电极位置
Acta Otolaryngol. 2009 Sep;129(9):966-70. doi: 10.1080/00016480802495388.