• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Balloon electric shock ablation. A surgical technique for treatment of ventricular tachycardia: influence of endocardial scar on depth of ablation achieved.

作者信息

Mickleborough L L, Mizuno S, Usui A, Wilson G, McComb D, Gray G

机构信息

Division of Cardiovascular Surgery, Toronto Hospital, University of Toronto, Ontario, Canada.

出版信息

J Thorac Cardiovasc Surg. 1994 Nov;108(5):855-61.

PMID:7967667
Abstract

Balloon electric shock ablation is a surgical technique that has been used for treatment of ventricular tachycardia. However, little is known about the energy requirements and precise electrode array best suited to achieve effective ablation of the target area while limiting injury to the surrounding myocardium. This study was designed to determine the effects of endocardial scar (often present at the "site of origin" of clinical ventricular tachycardia) on depth of ablation resulting from balloon electric shock ablation. A chronic canine model of endocardial scar (3.9 +/- 0.6 mm thick) was developed with the use of balloon electric shock ablation techniques. We compared depth of ablation achieved with balloon electric shock ablation with low-energy shocks (22 J per bead) in normal dogs versus those with chronic endocardial scar. No difference was found in depth of ablation in normal dogs and in the scar model (7.2 +/- 1.2 mm versus 6.2 +/- 1.0 mm). Depth of injury expressed as a percentage of wall thickness was not different in the two groups (61% +/- 11% versus 57% +/- 3%). We conclude that the presence of endocardial scar does not influence depth of injury resulting from balloon electric shock ablation. This data provides guidance for clinical application of the technique as a "closed heart" surgical approach for control of ventricular tachycardia. The data are also discussed in relation to energy levels currently used for direct current catheter ablation in patients with ventricular tachycardia.

摘要

相似文献

1
Balloon electric shock ablation. A surgical technique for treatment of ventricular tachycardia: influence of endocardial scar on depth of ablation achieved.
J Thorac Cardiovasc Surg. 1994 Nov;108(5):855-61.
2
Balloon electric shock ablation. Effects on ventricular structure, function, and electrophysiology.球囊电击消融术。对心室结构、功能及电生理的影响。
J Thorac Cardiovasc Surg. 1989 Jan;97(1):135-46.
3
Long-term outcomes of combined epicardial and endocardial ablation of monomorphic ventricular tachycardia related to hypertrophic cardiomyopathy.肥厚型心肌病相关单形性室性心动过速的心脏心外膜和心内膜联合消融的长期结果。
Circ Arrhythm Electrophysiol. 2011 Apr;4(2):185-94. doi: 10.1161/CIRCEP.110.957290. Epub 2011 Jan 26.
4
Surgical treatment of ventricular tachycardia by balloon electric shock ablation. Potential effects on the mitral valve apparatus.
J Thorac Cardiovasc Surg. 1992 Apr;103(4):629-37.
5
Endocardial ablation to eliminate epicardial arrhythmia substrate in scar-related ventricular tachycardia.心内膜消融消除与瘢痕相关的室性心动过速中的心外膜心律失常基质。
J Am Coll Cardiol. 2014 Apr 15;63(14):1416-26. doi: 10.1016/j.jacc.2013.10.087. Epub 2014 Jan 30.
6
Lack of uniform progression of endocardial scar in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy and ventricular tachycardia.致心律失常性右室心肌病/心疾病伴室性心动过速患者心内膜瘢痕缺乏一致性进展。
Circ Arrhythm Electrophysiol. 2010 Aug;3(4):332-8. doi: 10.1161/CIRCEP.109.919530. Epub 2010 Jun 17.
7
Endocardial mapping and ablation of tachycardia guided by noncontact balloon catheter mapping system.非接触式球囊导管标测系统引导下的心内膜标测及心动过速消融
Chin Med J (Engl). 2002 Jun;115(6):909-13.
8
Combined analysis of unipolar and bipolar voltage mapping identifies recurrences after unmappable scar-related ventricular tachycardia ablation.单相和双相电压标测的联合分析可识别无法标测的瘢痕相关室性心动过速消融后的复发。
Europace. 2015 Oct;17(10):1580-6. doi: 10.1093/europace/euv013. Epub 2015 Mar 6.
9
Endo-epicardial versus only-endocardial ablation as a first line strategy for the treatment of ventricular tachycardia in patients with ischemic heart disease.心外膜与心内膜联合消融与单纯心内膜消融作为缺血性心脏病患者室性心动过速一线治疗策略的比较。
Circ Arrhythm Electrophysiol. 2015 Aug;8(4):882-9. doi: 10.1161/CIRCEP.115.002827. Epub 2015 Jun 8.
10
Relation of the unipolar low-voltage penumbra surrounding the endocardial low-voltage scar to ventricular tachycardia circuit sites and ablation outcomes in ischemic cardiomyopathy.缺血性心肌病中心内膜低电压瘢痕周围单极低电压半暗带与室性心动过速折返环部位及消融结果的关系。
J Cardiovasc Electrophysiol. 2014 Jun;25(6):602-8. doi: 10.1111/jce.12393. Epub 2014 Mar 24.