Suppr超能文献

Captopril-enhanced 99Tcm-MAG3 renal scintigraphy in subjects with suspected renovascular hypertension.

作者信息

Kahn D, Ben-Haim S, Bushnell D L, Madsen M T, Kirchner P T

机构信息

University of Iowa College of Medicine, Department of Radiology, Iowa City 52242.

出版信息

Nucl Med Commun. 1994 Jul;15(7):515-28. doi: 10.1097/00006231-199407000-00005.

Abstract

This pilot study was undertaken to generate preliminary data on the accuracy of captopril-enhanced renal scintigraphy with a relatively new radiopharmaceutical, 99Tcm-mercaptoacetyltriglycine (99Tcm-MAG3) for detecting significant renal artery stenosis. Truth data was based either on arteriographic or outcome criteria (blood pressure response to therapy). Twenty-seven subjects with suspected renovascular hypertension were studied with baseline and captopril-enhanced 99Tcm-MAG3 renal scintigraphy and renal arteriography. Scan interpretations were expressed as a probability of a significant renal artery stenosis. Scan interpretations were compared with renal arteriographic results, renal vein renin levels, blood pressure values after renal artery repair, and blood pressure control after 4-26 months of clinical follow-up. Using > or = 50% luminal obstruction on arteriography as the reference standard for renal artery stenosis and a high probability scan representing a positive test, the test sensitivity and specificity were 33 and 97%, respectively (using high or indeterminate probability to represent a positive scan, the test sensitivity and specificity were 67 and 83%, respectively). The negative predictive value of a low probability scan for renal artery stenosis was 80%. However, including a measure of renovascular hypertension (blood pressure response to renal artery repair) as the reference standard, the accuracy of the scan improves, with the negative predictive value of a low probability scan for renovascular hypertension increasing to 97%. Scintigraphic results were also positively correlated with renal vein renin values in a statistically significant fashion (two-tailed Fisher exact test statistic = 6.43, P = 0.0219). Captopril-enhanced 99Tcm-MAG3 renal scintigraphy is a moderately accurate technique for detecting renal artery stenosis. More importantly, our preliminary findings suggest that the scintigraphic technique using 99Tcm-MAG3 appears to predict the blood pressure response to renal artery repair in subjects with suspected renovascular hypertension, thereby separating subjects with haemodynamically insignificant renal artery stenosis from those with renovascular hypertension.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验