Oram O, Gross R L, Severin T D, Feldman R M, Orengo-Nania S
Cullen Eye Institute, Baylor College of Medicine, Houston, Tex. 77030.
Ophthalmic Surg. 1994 Jul;25(7):449-51.
We have developed a cadaver eye model that allows anterior and posterior segment laser procedures to be performed under closely simulated in vivo conditions. The model consists of a reusable container with an artificial cornea with a refractive power and an anterior radius of curvature similar to those of the human cornea, and a fresh cadaver eye, prepared by removing the cornea and adjusting the biometric parameters to normal values. This cadaver eye model appears to be a valuable tool for teaching and practicing anterior and posterior segment laser procedures, as well as for research on new laser systems and applications.