Akhter J, Gaspar M, Bassuk A, Roberts J
Department of Pulmonology and Pediatrics, EHS Christ Hospital and Medical Center, Oak Lawn, IL 60453.
Pediatr Pulmonol. 1994 Jul;18(1):51-2. doi: 10.1002/ppul.1950180113.
We report the case of a 4-year-old child with an atypical presentation of an aspirated unwitnessed foreign body in the airway. During an attempt to obtain a biopsy of what appeared to be a mucosal growth, the foreign body was removed. This may be the first report of foreign body removal in a child this young, using a flexible fiberoptic bronchoscope.