Fijałek Z, Snycerski A
Drug Institute, School of Medicine, Warsaw, Poland.
Acta Pol Pharm. 1994;51(1):1-5.
Polarographic and voltammetric methods were used to study drugs of anthrone derivatives: mitoxandrone (antineoplastic), emodin (cathartic) and chrysarobin (antipsoriatic) on mercury and glassy carbon electrodes. The surface-active properties were exploited for developing a highly sensitive adsorptive stripping voltammetric method for determination of trace amounts of these compounds. Effective pre-concentration was obtained at glassy carbon electrode, with the surface species being measured via its reduction or oxidation, respectively. It was concluded that observed cathodic and anodic currents had the diffusive character. A simple, quick and accurate methods for the determination of all studied compounds in pure form and mitoxantrone in vials have been developed. The acetate buffer pH 4.6 containing 5 to 30% ethanol was used as a supporting electrolyte. The linear calibration range was 0.5 = 100 microg cm-3 on mercury and 25 - 250 ng cm-3 on glassy carbon electrode.
米托蒽醌(抗肿瘤药)、大黄素(泻药)和柯桠素(抗银屑病药)。利用其表面活性性质开发了一种高灵敏度吸附溶出伏安法用于测定痕量的这些化合物。在玻碳电极上实现了有效的预富集,通过其还原或氧化分别测量表面物种。得出观察到的阴极和阳极电流具有扩散特性的结论。已开发出一种简单、快速且准确的方法用于测定纯形式的所有研究化合物以及小瓶中的米托蒽醌。含有5%至30%乙醇的pH 4.6乙酸盐缓冲液用作支持电解质。在汞电极上线性校准范围为0.5 = 100 μg cm-3,在玻碳电极上为25 - 250 ng cm-3。