Relationship of the pelvic angle to the sacral angle: measurement of clinical reliability and validity.

作者信息

Gilliam J, Brunt D, MacMillan M, Kinard R E, Montgomery W J

机构信息

Department of Physical Therapy, University of Florida, Gainesville.

出版信息

J Orthop Sports Phys Ther. 1994 Oct;20(4):193-9. doi: 10.2519/jospt.1994.20.4.193.

Abstract

There is a need to better document the reliability and validity of assessment measures used in physical therapy. Studies documenting the reliability of measurement of the pelvic angle and its relationship to sacral motion are presently inconclusive. The purpose of this study was twofold. First, we wanted to determine the reliability and validity of a goniometric measurement of the pelvic angle. We also wanted to test the hypothesis that there is a relationship between the pelvic angle and the sacral angle. Intertester and intratester reliability of goniometric pelvic angle measurements of 23 healthy young adults were examined using three different raters. Radiographic measurements of the pelvic and sacral angle using two raters and goniometric measurement of the pelvic angle using a single rater were taken from 15 patients with low back pain who had been referred for X-rays. Intraclass correlation coefficients (ICCs) of intratester reliability for goniometric measurements of the pelvic angle were .93, .96, and .96. The intertester reliability was .95. The ICCs for intratester reliability for radiological measurements were .92 and .95 for the sacral angle and .98 for both measurements of the pelvic angle. Intertester reliability coefficients were .86 and .88, respectively. The Pearson correlation coefficients for the goniometric and radiological measurements of the pelvic angle were .85 and .68. A comparison of the radiological and goniometric measurements of the pelvic angle with the sacral angle demonstrated low average correlations of .43 and .58, respectively. The results indicate a high level of correlation between and within testers for goniometric measurements of the pelvic angle but only a fair correlation between goniometric and radiological measurements of the pelvic angle.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

有必要更好地记录物理治疗中所使用评估措施的可靠性和有效性。记录骨盆角度测量的可靠性及其与骶骨运动关系的研究目前尚无定论。本研究有两个目的。首先,我们想确定骨盆角度测角法测量的可靠性和有效性。我们还想检验骨盆角度与骶骨角度之间存在关联这一假设。使用三名不同的评估者,对23名健康年轻成年人的骨盆角度测角法测量进行了评估者间和评估者内可靠性检测。从15名因腰痛而转诊进行X光检查的患者中,由两名评估者进行骨盆和骶骨角度的影像学测量,以及由一名评估者进行骨盆角度的测角法测量。骨盆角度测角法测量的评估者内可靠性的组内相关系数(ICC)分别为0.93、0.96和0.96。评估者间可靠性为0.95。骶骨角度影像学测量的评估者内可靠性ICC分别为0.92和0.95,骨盆角度两次测量的ICC均为0.98。评估者间可靠性系数分别为0.86和0.88。骨盆角度测角法和影像学测量的皮尔逊相关系数分别为0.85和0.68。骨盆角度的影像学测量和测角法测量与骶骨角度的比较显示,平均相关性较低,分别为0.43和0.58。结果表明,评估者间和评估者内骨盆角度测角法测量之间具有高度相关性,但骨盆角度测角法和影像学测量之间只有中等相关性。(摘要截短于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验