van Rhenen D J, Vermeij H, Kappers-Klunne M, Payrat J M
Red Cross Bloodbank, Rotterdam, the Netherlands.
Transfusion. 1995 Jan;35(1):50-3. doi: 10.1046/j.1537-2995.1995.35195090662.x.
A new citrate-acetate-NaCl platelet additive solution, identified as PAS 2, was developed to prepare platelet concentrates (PCs) from pooled 0.5 CPD buffy coats (BCs).
A study was undertaken to evaluate PAS 2 in vitro (n = 8) and in vivo (n = 9) against a commercially available solution (Plasma-Lyte A). In a paired in vitro study, a comparison was made of platelet and white cell concentration; blood gases and bicarbonate; glucose and lactate concentration; total intracellular concentration of adenine nucleotides and beta-thromboglobulin release.
A lower platelet yield (p < 0.0001) and a higher beta-thromboglobulin release (p < 0.01) are observed with Plasma-Lyte A. For this reason, half-strength (0.5) CPD was changed to full-strength CPD in the clinical study with Plasma-Lyte A. In a clinical evaluation of nine patients with bone marrow failure, all received PCs with both PAS 2 and Plasma-Lyte A that had a shelf life of at least 4 days. Corrected count increments (CCls) were as follows, on average (95% Cl): the CCl at 1 to 4 hours was 22.4 (95% Cl, 15.2-29.4) for PAS 2 and 24.0 (95% Cl, 16.9-31.2) for Plasma-Lyte A; that at 12 to 24 hours was 11.3 (95% Cl, 4.1-18.4) for PAS 2 and 14.2 (95% Cl, 7.1-21.3) for Plasma-Lyte A; and that at 36 to 48 hours was 4.2 (95% Cl, -3.0-11.3) for PAS 2 and 8.7 (95% Cl, 1.1-16.2) for Plasma-Lyte A. No significant difference between the two solutions was found.
PAS 2 and Plasma-Lyte A make important contributions to platelet transfusion quality improvement and give an excellent CCl even after 4 days of storage.
一种新的柠檬酸盐 - 醋酸盐 - 氯化钠血小板添加剂溶液,命名为PAS 2,被开发用于从混合的0.5 CPD 白膜层(BCs)制备血小板浓缩物(PCs)。
开展了一项研究,在体外(n = 8)和体内(n = 9)对PAS 2与市售溶液(Plasma-Lyte A)进行评估。在一项配对体外研究中,比较了血小板和白细胞浓度;血气和碳酸氢盐;葡萄糖和乳酸浓度;腺嘌呤核苷酸的总细胞内浓度以及β-血小板球蛋白释放。
使用Plasma-Lyte A时观察到较低的血小板产量(p < 0.0001)和较高的β-血小板球蛋白释放(p < 0.01)。因此,在使用Plasma-Lyte A的临床研究中,将半强度(0.5)CPD改为全强度CPD。在对9名骨髓衰竭患者的临床评估中,所有患者均接受了保质期至少为4天的含PAS 2和Plasma-Lyte A的血小板浓缩物。校正计数增加值(CCls)如下,平均(95% 置信区间):1至4小时时,PAS 2的CCl为22.4(95% 置信区间,15.2 - 29.4),Plasma-Lyte A的CCl为24.0(95% 置信区间,16.9 - 31.2);12至24小时时,PAS 2的CCl为11.3(95% 置信区间,4.1 - 18.4),Plasma-Lyte A的CCl为14.2(95% 置信区间,7.1 - 21.3);36至48小时时,PAS 2的CCl为4.2(95% 置信区间,-3.0 - 11.3),Plasma-Lyte A的CCl为8.7(95% 置信区间,1.1 - 16.2)。两种溶液之间未发现显著差异。
PAS 2和Plasma-Lyte A对改善血小板输血质量有重要贡献,即使在储存4天后仍能提供出色的校正计数增加值。