Khodadadeh S
Orthotic Research and Locomotor Assessment Unit, Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire, UK.
J Med Eng Technol. 1994 Jan-Feb;18(1):22-8. doi: 10.3109/03091909409030784.
Several parameters used in the assessment of pathological gait are normally determined by measurements obtained by means other than from force plate recordings. Methods are presented whereby parameters such as stride length, step length, cadence, single support time, average forward velocity and angle of foot in contact with the force plate are determined directly from force plate recordings of the gait.
评估病理性步态时使用的几个参数通常通过除测力板记录之外的其他方法获得的测量值来确定。本文介绍了一些方法,通过这些方法可以直接从步态的测力板记录中确定步幅、步长、步频、单支撑时间、平均前进速度以及与测力板接触时的足部角度等参数。