Suppr超能文献

猛禽正常眼睛的眼压测量法

Tonometry of normal eyes in raptors.

作者信息

Stiles J, Buyukmihci N C, Farver T B

机构信息

Department of Surgery, School of Veterinary Medicine, University of California, Davis 95616-8745.

出版信息

Am J Vet Res. 1994 Apr;55(4):477-9.

PMID:8017692
Abstract

An applanation tonometer was used to estimate intraocular pressure in normal eyes of several species of raptors. No bird had active injury or illness, though some were nonreleasable to the wild because of previous injury. Mean (+/- SD) intraocular pressure was 20.6 (+/- 3.4) mm of Hg in red-tailed hawks (Buteo jamaicensis, n = 10), 20.8 (+/- 2.3) mm of Hg in Swainson's hawks (Buteo swainsoni, n = 6), 21.5 (+/- 3.0) mm of Hg in golden eagles (Aquila chrysaetos, n = 7), 20.6 (+/- 2.0) mm of Hg in bald eagles (Haliaeetus leucocephalus, n = 3), and 10.8 (+/- 3.6) mm of Hg in great horned owls (Bubo virginianus, n = 6). There was no significant difference in intraocular pressure between hawks and eagles. Mean pressure in great horned owls was significantly (P < 0.01) lower than pressure in hawks or eagles. Reliable intraocular pressure readings could not be obtained in barn owls (Tyto alba).

摘要

使用压平眼压计来估计几种猛禽正常眼睛的眼压。没有鸟有活动性损伤或疾病,不过有些鸟由于先前的损伤而无法放归野外。红尾鹰(赤肩鵟,n = 10)的平均(±标准差)眼压为20.6(±3.4)毫米汞柱,斯温氏鹰(斯温氏鵟,n = 6)为20.8(±2.3)毫米汞柱,金鹰(金雕,n = 7)为21.5(±3.0)毫米汞柱,白头鹰(白头海雕,n = 3)为20.6(±2.0)毫米汞柱,大角鸮(大雕鸮,n = 6)为10.8(±3.6)毫米汞柱。鹰和雕之间的眼压没有显著差异。大角鸮的平均眼压显著低于鹰或雕(P < 0.01)。在仓鸮(草鸮)中无法获得可靠的眼压读数。