BACKGROUND

Long-term maintenance of arterial duct patency by a catheter technique would be a valuable nonsurgical method of palliation for duct-dependent circulations. We used a new method: percutaneous radiofrequency thermal balloon angioplasty of neonatal lamb arterial ducts.

METHODS AND RESULTS

Radiofrequency balloons 5 or 6 mm in diameter were introduced via the femoral vein of 32 neonatal lambs and inflated to 4 atm. In 28, a radiofrequency generator was used to heat the saline/contrast mixture in the balloon to 65 degrees C (n = 2), 75 degrees C (n = 2), 85 degrees C (n = 10), 100 degrees C (n = 8), and 120 degrees C (n = 6). In 4 lambs, angioplasty alone was performed. Lambs were recatheterized to assess patency at intervals up to 78 weeks. Immediate results showed the arterial duct to be patent in all cases, with a mean rise in systolic pulmonary artery pressure of 13 +/- 8 mm Hg and a mean rise in pulmonary artery oxygen saturation of 12 +/- 15%. With a mean follow-up of 45.7 +/- 28 weeks, 3 of the 4 (75%) angioplasty alone ducts closed, but only 5 of the 28 (18%) radiofrequency-treated ducts (P < .05). The mean rise in oxygen saturation between the superior vena cava and the pulmonary artery was 7.6 +/- 7% at last follow-up. Follow-up angiography of the arterial ducts showed the development of stenoses in all patent ducts.

CONCLUSIONS

Radiofrequency thermal balloon angioplasty leads to long-term arterial duct patency in lambs in > 80% of the treated group and is significantly more effective than balloon angioplasty alone.

摘要

背景

通过导管技术长期维持动脉导管通畅将是一种用于依赖动脉导管循环的有价值的非手术姑息治疗方法。我们采用了一种新方法:经皮射频热球囊血管成形术治疗新生羔羊动脉导管。

方法与结果

将直径5或6毫米的射频球囊经32只新生羔羊的股静脉置入并充气至4个大气压。其中28只使用射频发生器将球囊内的盐水/造影剂混合物加热至65℃(n = 2)、75℃(n = 2)、85℃(n = 10)、100℃(n = 8)和120℃(n = 6)。4只羔羊仅进行血管成形术。对羔羊进行再次插管以评估长达78周的通畅情况。即时结果显示所有病例的动脉导管均通畅,收缩期肺动脉压平均升高13±8毫米汞柱,肺动脉血氧饱和度平均升高12±15%。平均随访45.7±28周,仅行血管成形术的4只羔羊中有3只(75%)导管闭合,但接受射频治疗的28只羔羊中只有5只(18%)导管闭合(P < 0.05)。最后一次随访时上腔静脉与肺动脉之间的血氧饱和度平均升高7.6±7%。动脉导管的随访血管造影显示所有通畅导管均出现狭窄。

结论

射频热球囊血管成形术使超过80%的治疗组羔羊动脉导管长期通畅,且明显比单纯球囊血管成形术更有效。