Using quantitative sequential camera scintigraphy and simultaneous separated clearance determinations with 131-I-Hippuran and 169-Yb-EDTA renal function was measured applying a new surgical method which permits in-situ kidney perfusion and cooling in animals and patients. While mongrel dogs of 15 kg average weight (control group of N = 5) showed after 1 hour of normothermic ischaemia a postoperative delay of intrarenal transport of 131-I-Hippuran with reduction of 131-I-Hippuran and 169Yb-EDTA clearances, renal function returned to normal on the first postoperative day after 1-hour (N = 5) and 2-hour (N = 5) hypothermic ischaemia. In patients (N = 9) with hypothermic in-situ perfusion of between 40 and 92 min duration a transient postoperative delay of intrarenal 131-I-Hippuran transport and a reduction of the 131I-Hippuran clearance was observed which returned to almost normal 1 1/2 to 3 months after surgery. The results and the significance of the method discussed and are compared with clinical findings and with radiological and laboratory renal function studies.

摘要

采用定量序贯相机闪烁扫描法,并同时分别测定131-I-马尿酸和169-Yb-乙二胺四乙酸的清除率,运用一种新的手术方法测量肾功能,该方法可在动物和患者体内进行原位肾脏灌注和冷却。平均体重15千克的杂种犬(对照组,N = 5)在常温缺血1小时后,术后131-I-马尿酸的肾内转运延迟,131-I-马尿酸和169-Yb-乙二胺四乙酸清除率降低;而在低温缺血1小时(N = 5)和2小时(N = 5)后,肾功能在术后第一天恢复正常。在原位低温灌注持续时间为40至92分钟的患者(N = 9)中,观察到术后131-I-马尿酸肾内转运短暂延迟,131-I-马尿酸清除率降低,术后1个半月至3个月恢复至几乎正常水平。对该方法的结果及意义进行了讨论,并与临床发现以及放射学和实验室肾功能研究进行了比较。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验