Suppr超能文献

胆结石溶剂对常用导管的影响。

Effects of gallstone solvents on commonly used catheters.

作者信息

Long C A, Teplick S K, Brandon J C, Harb G H, Yan K, Baker M L

机构信息

Department of Radiology, University of Oklahoma Health Science Center, Oklahoma City.

出版信息

J Vasc Interv Radiol. 1994 May-Jun;5(3):479-84. doi: 10.1016/s1051-0443(94)71534-7.

Abstract

PURPOSE

To determine what interaction and effect different cholesterol gallstone solvents have on catheters used for gallstone chemolysis.

MATERIALS AND METHODS

Five types of catheters used for biliary procedures were chosen: polyethylene, Percuflex, silicon, Silitek, and polyurethane. The solvents chosen were methyl tert-butyl ether, ethyl propionate, isopropyl acetate, and N-propyl acetate. After incubation of the catheters in the solvents for 72 hours, they were air dried. Weight and area changes were determined for each catheter. Additionally, carbon-13 nuclear magnetic resonance (NMR) spectroscopy was performed for analysis of composition changes.

RESULTS

Three catheters--silicone, Silitek, and polyurethane--showed changes in their physical characteristics that would make them less desirable for stone chemolysis. The silicone catheter showed changes in elastic texture as well as marked weight reduction. The Silitek and polyurethane catheters had similar, but less dramatic changes. C-13 NMR analysis of collected solvents showed that commonly used plasticizers were leached out of some catheters.

CONCLUSION

These results suggest that all catheters are not suitable for use with all solvents. The choice of catheter should be made based on the solvent in use. The polyethylene catheter performed best under the conditions and endpoints used in this study.

摘要

目的

确定不同的胆固醇结石溶剂对用于结石化学溶解的导管有何种相互作用和影响。

材料与方法

选取了五种用于胆道手术的导管:聚乙烯导管、Percuflex导管、硅胶导管、Silitek导管和聚氨酯导管。所选用的溶剂为甲基叔丁基醚、丙酸乙酯、乙酸异丙酯和乙酸正丙酯。将导管在溶剂中孵育72小时后,进行风干。测定每根导管的重量和面积变化。此外,还进行了碳-13核磁共振(NMR)光谱分析以检测成分变化。

结果

三种导管——硅胶导管、Silitek导管和聚氨酯导管——的物理特性发生了变化,这使得它们不太适合用于结石化学溶解。硅胶导管的弹性质地发生了变化,重量也显著减轻。Silitek导管和聚氨酯导管有类似但不太明显的变化。对收集到的溶剂进行的碳-13 NMR分析表明,一些导管中的常用增塑剂被浸出。

结论

这些结果表明,并非所有导管都适用于所有溶剂。应根据所使用的溶剂来选择导管。在本研究使用的条件和终点下,聚乙烯导管表现最佳。