• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Method of simulated screen sensitometry for asymmetric, low crossover medical x-ray films.

作者信息

Dickerson R E, Haus A G, Baker C W

机构信息

Health Sciences Division, Eastman Kodak Co., Rochester, New York 14650.

出版信息

Med Phys. 1994 Apr;21(4):525-8. doi: 10.1118/1.597168.

DOI:10.1118/1.597168
PMID:8058018
Abstract

Recognition of the importance of performing simulated screen-light sensitometry of medical x-ray films for the purpose of processor quality control has increased over the past several years. As a result there is a greater need to provide new techniques for performing simulated screen-light sensitometry. Medical films with reduced intensifying screen-light crossover intended to achieve reduced blur and higher spatial resolution pose particular problems in doing simulated screen-light sensitometry if care is not taken to choose a proper simulated light sensitometer with the capability of simultaneous double-sided exposures. Misleading and incorrect sensitometric data can be obtained for film contrast evaluation if a single side exposure is used. Asymmetric, near-zero crossover films pose even greater problems as proper orientation of the film and proper degree of light output asymmetry need be achieved in order to obtain correct sensitometry. The films used in this study were three double emulsion films varying in crossover from 3% to 24%. Of the two very-low-crossover films, one had symmetric emulsion layers while the second featured emulsion layers which were asymmetric in terms of contrast and speed. Sensitometric data show several curve shapes with significant distortions, depending on orientation, for the asymmetric, low-crossover film when exposed using a single-sided exposure. Only by using a double-sided exposure and an appropriate neutral density filter to simulate the degree of screen-light asymmetry in this system could one achieve a characteristic curve comparable to that achieved by inverse square sensitometry.

摘要

相似文献

1
Method of simulated screen sensitometry for asymmetric, low crossover medical x-ray films.
Med Phys. 1994 Apr;21(4):525-8. doi: 10.1118/1.597168.
2
Problems associated with simulated light sensitometry for low-crossover medical x-ray films.低交叉医学X光胶片模拟光密度测定法相关问题。
Med Phys. 1990 Jul-Aug;17(4):691-5. doi: 10.1118/1.596468.
3
Comparison of light and x-ray sensitometric responses of double-emulsion films for different processing conditions.不同冲洗条件下双乳剂胶片的光和X射线感光测定响应比较。
Med Phys. 2001 Dec;28(12):2420-6. doi: 10.1118/1.1418723.
4
Using light sensitometry to evaluate mammography film performance.
Med Phys. 2000 May;27(5):854-60. doi: 10.1118/1.598996.
5
Processor quality control in laser imaging systems.激光成像系统中的处理器质量控制
Med Phys. 1997 Apr;24(4):581-4. doi: 10.1118/1.597940.
6
Sensitometric responses of selected medical radiographic films.所选医用X线胶片的感光测定响应
Radiology. 1991 Dec;181(3):879-83. doi: 10.1148/radiology.181.3.1947114.
7
Image quality and breast dose of 24 screen-film combinations for mammography.用于乳腺摄影的24种屏-片组合的图像质量和乳腺剂量
Br J Radiol. 2006 Feb;79(938):123-9. doi: 10.1259/bjr/84646476.
8
Modified inverse square sensitometry for the determination of the characteristic curve of radiographic screen/film systems.
Acta Med Okayama. 1986 Feb;40(1):33-8. doi: 10.18926/AMO/31947.
9
Evaluation of resolution and sensitometric characteristics of an asymmetric screen-film imaging system.非对称增感屏-胶片成像系统的分辨率和感光特性评估。
Radiology. 1993 Aug;188(2):537-9. doi: 10.1148/radiology.188.2.8327711.
10
A time-scale sensitometric method for evaluating screen-film systems.一种用于评估增感屏-胶片系统的时间尺度感光测定方法。
Phys Med Biol. 1997 Oct;42(10):1939-46. doi: 10.1088/0031-9155/42/10/007.