Abstract

OBJECTIVE

Pituitary microadenomas may not be detected on conventional MR images. We supplemented conventional unenhanced and contrast-enhanced MR imaging with a dynamic keyhole fast spin-echo (kFSE) method in order to compare how frequently a microadenoma could be detected with the three different methods.

SUBJECTS AND METHODS

Eighteen consecutive patients with clinical and laboratory evidence of pituitary microadenomas had unenhanced, dynamic kFSE, and conventional contrast-enhanced MR imaging of the pituitary gland. A control group of 13 subjects without pituitary disease also had dynamic kFSE MR imaging. Hard copies of all the studies were obtained in an identical fashion, and then the MR images of the patients and control subjects were randomly mixed. The studies were reviewed by a neuroradiologist who had no knowledge of the clinical status of the subjects. The presence or absence of any pituitary focal hypointensity consistent with the appearance of a microadenoma was noted.

RESULTS

A pituitary lesion consistent in appearance with a microadenoma was detected on dynamic kFSE images in 13 of the 18 patients, on unenhanced images in nine patients, and on conventional contrast-enhanced images in 10 patients. In four patients, a microadenoma was detected on dynamic kFSE images only. Dynamic kFSE images showed a lesion in four of the 13 control subjects.

CONCLUSION

Dynamic kFSE MR imaging is a useful supplemental sequence in patients undergoing MR imaging because of pituitary endocrinopathy. It may show lesions that would otherwise escape detection.

摘要

目的

垂体微腺瘤在传统磁共振成像(MR)上可能无法被检测到。我们采用动态锁孔快速自旋回波(kFSE)方法对传统的平扫及增强MR成像进行补充,以比较这三种不同方法检测微腺瘤的频率。

对象与方法

连续纳入18例有垂体微腺瘤临床及实验室证据的患者,对其垂体进行平扫、动态kFSE及传统增强MR成像检查。13例无垂体疾病的受试者作为对照组,同样接受动态kFSE MR成像检查。所有检查均以相同方式获取硬拷贝,然后将患者和对照受试者的MR图像随机混合。由一名对受试者临床状况不知情的神经放射科医生对这些检查进行评估。记录是否存在与微腺瘤表现一致的垂体局灶性低信号。

结果

18例患者中,13例在动态kFSE图像上检测到与微腺瘤外观一致的垂体病变,9例在平扫图像上检测到,10例在传统增强图像上检测到。4例患者仅在动态kFSE图像上检测到微腺瘤。13例对照受试者中有4例在动态kFSE图像上显示有病变。

结论

对于因垂体内分泌病变而接受MR成像检查的患者,动态kFSE MR成像是一种有用的补充序列。它可能显示出其他方法无法检测到的病变。