Martin S, Liggett H, Robson A, Connolly J, Johnson R W
NW Regional Tissue Typing Laboratory, St Mary's Hospital, Manchester, UK.
Transpl Immunol. 1993;1(4):270-6. doi: 10.1016/0966-3274(93)90035-7.
Between January 1989 and June 1991 329 consecutive cadaveric renal transplants were carried out at this centre and, of those, 36 (10.9%) have failed. In order to assess whether the use of flow cytometry crossmatching (FCXM) would have predicted these failures, we carried out a retrospective T and B cell FCXM study comparing the failure group with a control group of 30 recipients carefully selected from patients transplanted during the same period. The number of first and second transplants in the control and failure groups was 25,5 and 23,8 respectively with six of the controls and three of the failures having panel reactive lymphocytotoxic antibodies > 50%. Stored donor material was available for 31 of the 36 failures. Two colour FCXM was performed using R-phycoerythrin-conjugated antihuman CD3 and antihuman CD19 to identify T and B cells respectively. For each recipient, three pretransplant and one post-transplant sera were tested against lymphocytes from the recipient's kidney donor. A fluorescein isothiocyanate conjugated F(ab')2 rabbit antihuman IgG was used to detect recipient IgG alloantibodies bound to donor T and/or B cells. There were no T or B cell FCXM positive (+) results in the control group whereas 11 of the 31 (35%) failures overall and nine of the 23 (39%) who failed within three months were T and B cell FCXM+ pretransplant (p = 0.0002). Seven of the nine FCXM+ results in the early failure group were with historic sera and two with historic and current sera.(ABSTRACT TRUNCATED AT 250 WORDS)