In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the central region. Injected current EIT, with Sheffield data collection protocol, and induced current EIT, with two different coil configurations, are compared with respect to singular-value patterns, sensitivity distributions and imaging performances. It is observed that for the proposed alternative coil configuration the measurements are more sensitive to inner region conductivity perturbations when compared to injected current EIT and induced current EIT using circular coils. The images obtained by induced current EIT are comparable to that obtained by injected current EIT.

摘要

在本研究中,对使用圆形线圈的感应电流电阻抗断层成像(EIT)的线圈配置参数(线圈半径和线圈中心偏移)的选择进行了研究。提出了一种替代线圈配置,其产生近似线性(空间上)的磁场,以增强中心区域的电流。将采用谢菲尔德数据采集协议的注入电流EIT以及具有两种不同线圈配置的感应电流EIT,在奇异值模式、灵敏度分布和成像性能方面进行了比较。观察到,与注入电流EIT和使用圆形线圈的感应电流EIT相比,对于所提出的替代线圈配置,测量对内部区域电导率扰动更为敏感。感应电流EIT获得的图像与注入电流EIT获得的图像相当。