Krämer H J, Stevens J, Seeger W
Department of Internal Medicine, Giessen, Federal Republic of Germany.
Anal Biochem. 1993 Nov 1;214(2):535-43. doi: 10.1006/abio.1993.1535.
Measurement of cyclooxygenase products of both arachidonic acid and eicosapentaenoic acid is of broad interest due to the wide and diverse biological activities of these compounds. We developed a technique combining (i) solid-phase extraction, (ii) reversed-phase HPLC separation using a high-capacity column, and (iii) post-HPLC enzyme-linked immunosorbant assay (ELISAs) employing monoclonal antibodies for quantification of all main 2- and 3-series prostanoids within one run. Thermal and chemical stress on these labile agents was reduced by use of ionic pair reagent and high buffer strength for processing at neutral pH, alpha-tocopherole as antioxidant, and freeze-drying evaporation during critical steps of the analytical procedure. With these techniques, mixtures of 2- and 3-series prostanoids (thromboxane (Tx)B2/3, 6-keto-prostaglandin (PG)F1 alpha/2 alpha, PGF2 alpha/3 alpha, PGF2/3) were recovered from Krebs-Henseleit buffer with linear characteristics for each compound in the range between 50 and 500 pg/ml. Percentages of overall recovery ranged between 45 and 90% for the different prostanoids with satisfying reproducibility. Application of the technique to a perfused rabbit lung and human platelets challenged with free eicosapentaenoic acid demonstrated marked generation of TxB3; quantities of this trienoic prostanoid as assessed by HPLC/ELISA were well correlated to those obtained by GC/MS. Thus, convenient quantification of 2- and 3-series prostanoids in media of biological interest is achieved by combined chromatographic and immunological techniques.
由于花生四烯酸和二十碳五烯酸的环氧化酶产物具有广泛多样的生物活性,因此对其进行测量具有广泛的研究意义。我们开发了一种技术,该技术结合了:(i)固相萃取;(ii)使用高容量柱的反相高效液相色谱分离;以及(iii)高效液相色谱后的酶联免疫吸附测定(ELISA),采用单克隆抗体在一次运行中对所有主要的2-和3-系列前列腺素进行定量。通过使用离子对试剂和高缓冲强度在中性pH下进行处理、使用α-生育酚作为抗氧化剂以及在分析过程的关键步骤中进行冷冻干燥蒸发,减少了这些不稳定物质所受的热和化学应力。利用这些技术,从 Krebs-Henseleit 缓冲液中回收了2-和3-系列前列腺素混合物(血栓素(Tx)B2/3、6-酮-前列腺素(PG)F1α/2α、PGF2α/3α、PGF2/3),每种化合物在50至500 pg/ml范围内具有线性特征。不同前列腺素的总回收率在45%至90%之间,具有令人满意的重现性。将该技术应用于用游离二十碳五烯酸刺激的灌注兔肺和人血小板,结果表明生成了大量的TxB3;通过高效液相色谱/ELISA评估的这种三烯前列腺素的量与通过气相色谱/质谱法获得的量具有良好的相关性。因此,通过色谱和免疫技术的结合,可以方便地对生物相关介质中的2-和3-系列前列腺素进行定量。