Suppr超能文献

用于非骨水泥全膝关节置换术中固定胫骨部件的四颗螺钉。

Four screws for fixation of the tibial component in cementless total knee arthroplasty.

作者信息

Whiteside L A

机构信息

Biomechanical Research Laboratory, St. Louis, Missouri 63044.

出版信息

Clin Orthop Relat Res. 1994 Feb(299):72-6.

PMID:8119039
Abstract

Screw fixation of the tibial component offers advantages in fixation in cementless total knee arthroplasty (TKA). In a group of 447 cementless TKA tibial components fixed without screws, 24% had partial undersurface radiolucent lines and 3% had complete radiolucent lines. Both of these parameters were significantly decreased (p < 0.01) when screws were used. In a group of 1442 cementless tibial trays fixed with screws, 4% had partial and 0.1% had complete radiolucent lines. Cyst formation around smooth pegs was also more common in trays fixed without screws. Two of the 5758 screws inserted in 1442 trays developed nonprogressive radiolucent lines, but no case of major osteolysis has been seen. Although screw fixation of cementless tibial components appears to improve the metal-bone interface, the potential for long-term complications still exists. The use of screws should be reserved for difficult fixation problems.

摘要

在非骨水泥全膝关节置换术(TKA)中,胫骨部件的螺钉固定具有优势。在一组447个未用螺钉固定的非骨水泥TKA胫骨部件中,24%的部件下表面出现部分透光线,3%的部件出现完全透光线。使用螺钉时,这两个参数均显著降低(p < 0.01)。在一组1442个用螺钉固定的非骨水泥胫骨托中,4%的部件出现部分透光线,0.1%的部件出现完全透光线。在未用螺钉固定的托盘中,光滑栓周围的囊肿形成也更为常见。在1442个托盘中插入的5758枚螺钉中有2枚出现非进行性透光线,但未发现严重骨溶解病例。尽管非骨水泥胫骨部件的螺钉固定似乎改善了金属-骨界面,但长期并发症的可能性仍然存在。螺钉的使用应仅限于困难的固定问题。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验