Welt B A, Tong C H, Rossen J L, Lund D B
Department of Food Science, Cook College, Rutgers University, New Brunswick, New Jersey 08903.
Appl Environ Microbiol. 1994 Feb;60(2):482-8. doi: 10.1128/aem.60.2.482-488.1994.
Three techniques for studying effects of microwave radiation on microorganisms were introduced. Spores of Clostridium sporogenes (PA 3679) were chosen as a test organism because the kinetic parameters for thermal inactivation are well known and because of the importance of the genus Clostridium to the food industry. For the first technique, a specially designed kinetics vessel was used to compare inactivation rates of microwave-heated and conventionally heated spores at steady-state temperatures of 90, 100, and 110 degrees C. Rates were found to be similar at the 95% confidence level. The second and third techniques were designed to study the effect of relatively high power microwave exposure at sublethal temperatures. In the second approach, the suspension was continuously cooled via direct contact with a copper cooling coil in a well-mixed vessel, outside the microwave oven. The suspension was pumped through a Teflon loop in the oven, where it continuously absorbed approximately 400 W of microwave power. Inactivation occurred in both irradiated and unirradiated samples. It was suspected that copper ions entered the suspension from the copper coil and were toxic to the spores. The fact that the results were similar, however, implied the absence of nonthermal microwave effects. In the third approach, the copper coil was replaced with a silicone tubing loop in a microwave transparent vessel. The suspension was continuously irradiated at 150 W of microwave power. No detectable inactivation occurred. Results indicated that the effect of microwave energy on viability of spores was indistinguishable from the effect of conventional heating.
介绍了三种研究微波辐射对微生物影响的技术。选择生孢梭菌(PA 3679)的孢子作为测试生物体,这是因为热灭活的动力学参数是已知的,而且梭菌属对食品工业很重要。对于第一种技术,使用专门设计的动力学容器来比较在90、100和110摄氏度稳态温度下微波加热和传统加热孢子的失活速率。发现在95%置信水平下速率相似。第二种和第三种技术旨在研究亚致死温度下相对高功率微波暴露的影响。在第二种方法中,悬浮液通过与微波炉外充分混合容器中的铜冷却盘管直接接触而持续冷却。悬浮液通过烤箱中的聚四氟乙烯回路泵送,在那里它持续吸收约400瓦的微波功率。在辐照和未辐照的样品中均发生了失活。怀疑铜离子从铜盘管进入悬浮液并对孢子有毒。然而,结果相似这一事实意味着不存在非热微波效应。在第三种方法中,在微波透明容器中用硅酮管回路代替铜盘管。悬浮液以150瓦的微波功率持续辐照。未发生可检测到的失活。结果表明,微波能量对孢子活力的影响与传统加热的影响没有区别。